PPO(PPE) UNINOR® PPO Modified

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTMD7921.08 g/cm³
Water absorption rateASTMD5700.070 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTMD785119
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-0
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusASTMD6382550 MPa
tensile strengthYieldASTMD63863.4 MPa
elongationBreakASTMD63825 %
Flexural modulusASTMD7902550 MPa
bending strengthASTMD79099.3 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTMD256190 J/m
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityASTMD257>1.0E+15 ohms·cm
dielectric strengthASTMD14920 kV/mm
dielectric constantASTMD1502.70
Dissipation FactorASTMD1507E-04
Thermal performanceTest ConditionTest MethodTest Result
ASTMD648123 °C
Continuous use temperatureUL746110 °C
ASTMD3418254 °C
ASTMD6965.9E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.