Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPO(PPE) UNINOR® PPO Modified Nytef Plastics, Ltd.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Nytef Plastics, Ltd./UNINOR® PPO Modified |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256 | 190 J/m |
hardness | Test Condition | Test Method | Nytef Plastics, Ltd./UNINOR® PPO Modified |
---|---|---|---|
Rockwell hardness | R级 | ASTM D785 | 119 |
Mechanical properties | Test Condition | Test Method | Nytef Plastics, Ltd./UNINOR® PPO Modified |
---|---|---|---|
elongation | 断裂 | ASTM D638 | 25 % |
Tensile modulus | ASTM D638 | 2550 MPa | |
Flexural modulus | ASTM D790 | 2550 MPa | |
tensile strength | 屈服 | ASTM D638 | 63.4 MPa |
bending strength | ASTM D790 | 99.3 MPa |
Electrical performance | Test Condition | Test Method | Nytef Plastics, Ltd./UNINOR® PPO Modified |
---|---|---|---|
Dissipation Factor | 60Hz | ASTM D150 | 7E-04 |
dielectric constant | 60Hz | ASTM D150 | 2.70 |
Volume resistivity | ASTM D257 | >1.0E+15 ohms·cm | |
dielectric strength | ASTM D149 | 20 kV/mm |
flammability | Test Condition | Test Method | Nytef Plastics, Ltd./UNINOR® PPO Modified |
---|---|---|---|
UL flame retardant rating | 6.1mm | UL 94 | V-0 |
physical property | Test Condition | Test Method | Nytef Plastics, Ltd./UNINOR® PPO Modified |
---|---|---|---|
Water absorption rate | 24hr | ASTM D570 | 0.070 % |
density | ASTM D792 | 1.08 g/cm³ |
Thermal performance | Test Condition | Test Method | Nytef Plastics, Ltd./UNINOR® PPO Modified |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | ASTM D648 | 123 °C |
Linear coefficient of thermal expansion | MD | ASTM D696 | 5.9E-05 cm/cm/°C |
melting temperature | ASTM D3418 | 254 °C | |
Continuous use temperature | UL 746 | 110 °C |
Contact Us
Get App
Top