PA66 UNITIKA E-RUNG60
32
- Properties:Glass fiber reinforcedenhance
- Usages:Electrical componentsVehicle electronicsElectronic fieldElectrical field
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 0.3 % | |
ISO 294-4 | 0.1 % | ||
Water absorption rate | ISO 62 | 0.7 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | ISO 2039-2 | 120 | |
Tensile modulus | ISO 527-2 | 19000 Mpa | |
Tensile stress | ISO 527-2 | 240 Mpa | |
Tensile strain | ISO 527-2 | 1.8 % | |
Flexural modulus | ISO 178 | 18600 Mpa | |
bending strength | ISO 178 | 370 Mpa | |
Charpy Notched Impact Strength | ISO 179 | 16 kJ/m² | |
ISO 179 | 80 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | IEC 60093 | 1E+15 | |
dielectric strength | IEC 60243-1 | 35 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 175-2/B | 250 °C | |
ISO 175-2/A | 225 °C | ||
Linear coefficient of thermal expansion | ISO 11359-2 | 0.000025 cm/cm/℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.