Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
ThermalConductivityofMelt | | | 0.23 W/m/K |
density | | ISO 1183 | 1.14 g/cm³ |
Melt volume flow rate | | ISO 1133 | 17.0 cm³/10min |
Shrinkage rate | | ISO 294-4 | 0.60 % |
Water absorption rate | | ISO 62 | 0.50 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | IEC 60695-11-10,-20 | HB |
UL flame retardant rating | | IEC 60695-11-10,-20 | HB |
Burning wire flammability index | | IEC 60695-2-12 | 725 °C |
Burning wire flammability index | | IEC 60695-2-12 | 700 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 750 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 725 °C |
Limiting Oxygen Index | | ISO 4589-2 | 23 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO 180/4A | 70 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 20 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 40 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | NoBreak |
Impact strength of simply supported beam without notch | | ISO 179/1eU | NoBreak |
Impact strength of cantilever beam gap | | ISO 180/4A | 35 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/4A | 60 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile strain | Yield | ISO 527-2 | 5.0 % |
Nominal tensile fracture strain | | ISO 527-2 | >50 % |
Flexural modulus | | ISO 178 | 2300 MPa |
bending strength | | ISO 178 | 85.0 MPa |
Tensile modulus | | ISO 527-2 | 2300 MPa |
tensile strength | Yield | ISO 527-2 | 55.0 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 | >1.0E+15 ohms |
Volume resistivity | | IEC 60093 | >1.0E+15 ohms·cm |
dielectric strength | | IEC 60243-1 | 35 kV/mm |
relative permittivity | | IEC 60250 | 2.90 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 2 |
Compared to the Leakage Tracking Index (CTI) | | UL 746 | PLC 2 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Linear coefficient of thermal expansion | | ISO 11359-2 | 7E-05 cm/cm/°C |
Heat distortion temperature | | ISO 75-2/A | 110 °C |
vicat | | ISO 306/B50 | 130 °C |
ball-indentation hardness | | IEC 60695-10-2 | Pass |
Linear coefficient of thermal expansion | | ISO 11359-2 | 7E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.