PC XANTAR® C CM 506 U

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
ThermalConductivityofMelt0.23 W/m/K
densityISO 11831.14 g/cm³
Melt volume flow rateISO 113317.0 cm³/10min
Shrinkage rateISO 294-40.60 %
Water absorption rateISO 620.50 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingIEC 60695-11-10,-20HB
UL flame retardant ratingIEC 60695-11-10,-20HB
Burning wire flammability indexIEC 60695-2-12725 °C
Burning wire flammability indexIEC 60695-2-12700 °C
Hot filament ignition temperatureIEC 60695-2-13750 °C
Hot filament ignition temperatureIEC 60695-2-13725 °C
Limiting Oxygen IndexISO 4589-223 %
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapISO 180/4A70 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA20 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA40 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Impact strength of cantilever beam gapISO 180/4A35 kJ/m²
Impact strength of cantilever beam gapISO 180/4A60 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile strainYieldISO 527-25.0 %
Nominal tensile fracture strainISO 527-2>50 %
Flexural modulusISO 1782300 MPa
bending strengthISO 17885.0 MPa
Tensile modulusISO 527-22300 MPa
tensile strength YieldISO 527-255.0 MPa
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC 60093>1.0E+15 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric strengthIEC 60243-135 kV/mm
relative permittivityIEC 602502.90
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 2
Compared to the Leakage Tracking Index (CTI)UL 746PLC 2
Thermal performanceTest ConditionTest MethodTest Result
Linear coefficient of thermal expansionISO 11359-27E-05 cm/cm/°C
Heat distortion temperatureISO 75-2/A110 °C
vicatISO 306/B50130 °C
ball-indentation hardnessIEC 60695-10-2Pass
Linear coefficient of thermal expansionISO 11359-27E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.