PA6 230 GH Chem Polymer Company

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight
  • Usages:
    Application in the automotive field

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.36 g/cm³
Shrinkage rateISO 294-40.15to0.40 %
flammabilityTest ConditionTest MethodTest Result
Limiting Oxygen IndexISO 4589-222 %
FMVSS flammabilityFMVSS302Passed
UL flame retardant ratingUL 94HB
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strength YieldISO 527-2158 MPa
Tensile strainYieldISO 527-23.0 %
Tensile strainBreakISO 527-23.0 %
Flexural modulusISO 1788100 MPa
bending strengthISO 178225 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapISO 180/1A9.0 kJ/m²
Impact strength of cantilever beam gapISO 180/1A11 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityISO 13251E+15 ohms·cm
dielectric strengthASTM D14911 kV/mm
Compared to the Leakage Tracking Index (CTI)内部方法PLC 0
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/A200 °C
melting temperatureASTM D789220 °C
Linear coefficient of thermal expansionASTM D6965.3E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.