COC APEL™ APL6011T MITSUI CHEM JAPAN
15
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Refractive index | ASTM D542 | 1.540 | |
| Transmittance rate | ASTM D1003 | 90.0 % | |
| turbidity | ASTM D1003 | 3.0 % |
| Basic Performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| melt mass-flow rate | ASTM D1238 | 26 g/10min | |
| density | ASTM D792 | 1.03 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 25 J/m | |
| bending strength | ASTM D790 | 110 Mpa | |
| Bending modulus | ASTM D790 | 2700 Mpa | |
| elongation | Break | ASTM D638 | 3.0 % |
| tensile strength | ASTM D638 | 60 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 95 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | ASTM D955 | 0.006 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.