Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.40 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
burning rate | | UL94 | 27 mm/min |
UL flame retardant rating | | UL94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTMD638 | 3720 MPa |
elongation | Break | ASTMD638 | 0.78 % |
Flexural modulus | | ASTMD790 | 8710 MPa |
bending strength | | ASTMD790 | 114 MPa |
tensile strength | Break | ASTMD638 | 80.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 59 J/m |
Suspended wall beam without notch impact strength | | ASTMD256 | 160 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ESDSTM11.11 | 30 ohms |
Volume resistivity | | ASTMD257 | 7.5E+02 ohms·cm |
StaticDecay | | 内部方法 | 10 msec |
Surface Resistance | | ESDSTM11.11 | 300 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|
thermal conductivity | | ASTMD5470 | 2.7 W/m/K |
Heat distortion temperature | | ASTMD648 | 216 °C |
| | ASTMD696 | 2.8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.