SPS XAREC™ S136 IDEMITSU JAPAN
39
- Properties:Glass fiber reinforcedHigh temperature resistan
- Usages:Electrical applicationsHousehold daily necessities
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | 23℃23℃ | ISO 179 | 10 kJ/m² |
| Impact strength of simply supported beam without notch | 23℃23℃ | ISO 179 | 28 kJ/m² |
| Impact strength of cantilever beam gap | 23℃23℃ | ISO 180 | 9 kJ/m² |
| Suspended wall beam without notch impact strength | 23℃23℃ | ISO 180 | 29 kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | ISO 527-2 | 10600 Mpa | |
| tensile strength | BreakBreak | ISO 527-2 | 115 Mpa |
| Tensile strain | BreakBreak | ISO 527-2 | 1.6 % |
| Bending modulus | ISO 178 | 10000 Mpa | |
| bending strength | ISO 178 | 170 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8 MPa,Unannealed1.8 MPa,Unannealed | ISO 75-2/A | 245 °C |
| 0.45 MPa,Unannealed | ISO 75-2/B | 265 °C | |
| Linear coefficient of thermal expansion | TD:-30~30℃TD:-30 to 30℃ | TMA | 0.000040 1/℃ |
| MD:-30~30℃MD:-30 to 30℃ | TMA | 0.000020 1/℃ | |
| Relative Heat Index (RTI) | 电气性能 | UL 746 | 50 °C |
| 强度机械性能 | UL 746 | 50 °C | |
| 冲击机械性能 | UL 746 | 50 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ISO 1183 | 1.42 g/cm³ | |
| Shrinkage rate | TDAcross Flow | Internal Method | 0.50 - 0.80 % |
| MDFlow | Internal Method | 0.10 - 0.40 % | |
| Water absorption rate | Equilibrium,23℃,50% RHEquilibrium,23℃,50% RH2 | ISO 62 | 0.02 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | IEC 60093 | > 1.0E+16 ohms·cm | |
| Dielectric strength | ASTM D149 | 35 KV/mm | |
| Dielectric constant | 1 MHz1 MHz | IEC 60250 | 3 |
| Dissipation factor | 1 MHz1 MHz | IEC 60250 | 0.002 |
| Arc resistance | ASTM D495 | PLC 6 | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 |
| flame retardant performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| > 1.50 mm> 1.5 mm | UL 94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.