ABS STAREX®  SF-0505

56
  • Properties:
    Flame retardant
    Thermal stability
    Aging resistance
  • Usages:
    Automotive components

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.11 g/cm³
densityISO 11831.11 g/cm³
melt mass-flow rateASTM D123817 g/10min
melt mass-flow rateISO 113317 g/10min
Shrinkage rateASTM D9550.30-0.60 %
Shrinkage rateISO 25770.30-0.60 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessASTM D785113
Rockwell hardnessISO 2039-2113
HardnessJISK5401F
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-2/502400 Mpa
tensile strength ASTM D63850.0 Mpa
tensile strength ISO 527-2/5056.0 Mpa
tensile strength ASTM D63839.0 Mpa
tensile strength ISO 527-2/5048.0 Mpa
elongationASTM D63811 %
Tensile strainISO 527-2/505.6 %
Flexural modulusASTM D7902300 Mpa
Flexural modulusISO 1782400 Mpa
bending strengthASTM D79071.0 Mpa
Tensile modulusASTM D6382400 Mpa
bending strengthISO 17881.0 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA5.3 kJ/m²
Impact strength of cantilever beam gapASTM D256110 J/m
Impact strength of cantilever beam gapISO 180/1A4.5 kJ/m²
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/A73.0 °C
vicatISO 306/B5094.0 °C
vicatISO 306/B12096.0 °C
Heat distortion temperatureASTM D64892.0 °C
Heat distortion temperatureISO 75-2/B84.0 °C
Heat distortion temperatureASTM D64884.0 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top