Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.62 g/cm³ |
melt mass-flow rate | | ASTM D1238 | 16 g/10min |
Melt volume flow rate | | ISO 1133 | 10.0 cm³/10min |
Shrinkage rate | | 内部方法 | 0.30to0.80 % |
Water absorption rate | | ISO 62 | 0.020 % |
Water absorption rate | | ISO 62 | 0.0 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Dart impact | | ASTM D3763 | 3.60 J |
Charpy Notched Impact Strength | | ISO 179/1eA | 35 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 37 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 34 J/m |
Impact strength of cantilever beam gap | | ISO 180/1A | 34 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 34 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTM D638 | 79.2 MPa |
tensile strength | Break | ISO 527-2/5 | 89.0 MPa |
elongation | | ASTM D638 | 0.64 % |
elongation | Yield | ISO 527-2/5 | 0.64 % |
elongation | | ASTM D638 | 0.66 % |
elongation | Break | ISO 527-2/5 | 0.66 % |
Flexural modulus | | ASTM D790 | 12700 MPa |
Flexural modulus | | ISO 178 | 13600 MPa |
bending strength | | ISO 178 | 0.980 MPa |
bending strength | | ASTM D790 | 118 MPa |
Tensile modulus | | ASTM D638 | 16300 MPa |
Tensile modulus | | ISO 527-2/1 | 15000 MPa |
tensile strength | | ASTM D638 | 79.2 MPa |
tensile strength | Yield | ISO 527-2/5 | 89.0 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTM D257 | 2.5E+04 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 234 °C |
Heat distortion temperature | | ISO 75-2/Ae | 229 °C |
vicat | | ASTMD152510 | 231 °C |
vicat | | ISO 306/B50 | 233 °C |
Linear coefficient of thermal expansion | | ASTME831 | 2.7E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | ASTME831 | 4.9E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.