Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.70to1.85 g/cm³ |
Shrinkage rate | | | 0.15to0.35 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 14000 MPa |
tensile strength | | ASTM D638 | 31.0 MPa |
Flexural modulus | | ASTM D790 | 9700 MPa |
bending strength | | ASTM D790 | 95.0 MPa |
Poisson's ratio | | | 0.30 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 370 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 480 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D149 | 15 kV/mm |
arc resistance | | ASTM D495 | 180 sec |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Linear coefficient of thermal expansion | | | 3.5E-05 cm/cm/°C |
thermal conductivity | | | 0.30 W/m/K |
RTI Elec | | UL 746 | 130 °C |
RTI Imp | | UL 746 | 130 °C |
RTI Str | | UL 746 | 130 °C |
Linear coefficient of thermal expansion | | | 2.5E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.