physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.20 g/cm³ | |
ISO 1183/A | 1.20 g/cm³ | ||
ISO 11832 | 1200 kg/m³ | ||
melt mass-flow rate | ASTM D1238 | 22 g/10min | |
ISO 1133 | 22 g/10min | ||
Melt volume flow rate | ISO 11332 | 18.0 cm³/10min | |
Shrinkage rate | ASTM D955 | 0.50to0.70 % | |
ISO 294-4 | 0.50to0.70 % | ||
Water absorption rate | ASTM D570 | 0.15 % | |
ISO 62 | 0.15 % | ||
ASTM D570 | 0.32 % | ||
ISO 62 | 0.32 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | ASTM D785 | 72 | |
R-Scale | ASTM D785 | 118 |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Haze ratio | ASTM D1003 | 1.0 % | |
refractive index | ASTM D542 | 1.586 | |
ISO 489 | 1.586 | ||
transmissivity | ASTM D1003 | 89.0 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | HB | |
Burning Behav. | ISO 12102 | HB | |
Burning Behav.atthicknessh | ISO 12102 | HB | |
Limiting Oxygen Index | ISO 4589-2 | 26 % | |
Limiting Oxygen Index (LOI) | ISO 4589-22 | 26 % | |
Average degree of combustion | ASTM D635 | 3 cm | |
UL flame retardant rating | UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 2340 MPa | |
ISO 527-2/50 | 2300 MPa | ||
ISO 527-22 | 2300 MPa | ||
tensile strength | Yield | ASTM D638 | 60.0 MPa |
bending strength | ASTM D790 | 96.5 MPa | |
ISO 178 | 97.0 MPa | ||
Taber abraser | ASTM D1044 | 45 % | |
tensile strength | Yield | ISO 527-2/50 | 60.0 MPa |
Yield | ISO 527-22 | 60.0 MPa | |
Break | ASTM D638 | 65.5 MPa | |
Break | ISO 527-2/50 | 66.0 MPa | |
Tensile strain | Yield | ISO 527-22 | 6.0 % |
elongation | Break | ASTM D638 | 120 % |
Tensile strain | Break | ISO 527-2/50 | 120 % |
Nominal fracture strain | ISO 527-22 | >50 % | |
Flexural modulus | ASTM D790 | 2410 MPa | |
ISO 178 | 2400 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA2 | 70.0 kJ/m² | |
ISO 179/1eA2 | 11.0 kJ/m² | ||
ISO 179/1eU2 | NoBreak | ||
ISO 179/1eU2 | NoBreak | ||
Impact strength of cantilever beam gap | ASTM D256 | 750 J/m | |
ISO 180/A | 74 kJ/m² | ||
ASTM D256 | NoBreak | ||
Suspended wall beam without notch impact strength | ISO 180 | NoBreak | |
InstrumentedDartImpact | ASTM D3763 | 72.3 J | |
Impact strength of cantilever beam gap | ASTM D1822 | 378 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation Factor | IEC 602502 | 1E-03 | |
IEC 602502 | 2E-03 | ||
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 2 | |
Volume resistivity | ASTM D257 | 2E+17 ohms·cm | |
IEC 600932 | >1.0E+13 ohms·m | ||
dielectric strength | ASTM D149 | 17 kV/mm | |
IEC 60243-1 | 17 kV/mm | ||
IEC 60243-12 | 17 kV/mm | ||
dielectric constant | ASTM D150 | 3.00 | |
ASTM D150 | 3.00 | ||
relative permittivity | IEC 602502 | 3.00 | |
IEC 602502 | 3.00 | ||
Dissipation Factor | ASTM D150 | 1E-03 | |
ASTM D150 | 2E-03 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 139 °C | |
ISO 75-2/A | 126 °C | ||
ISO 75-22 | 128 °C | ||
vicat | ASTM D15257 | 147 °C | |
ISO 306/B50 | 147 °C | ||
ISO 3062 | 147 °C | ||
Ball pressure temperature | IEC 60335-1 | 125 °C | |
Linear coefficient of thermal expansion | ASTM D696 | 6.8E-05 cm/cm/°C | |
ISO 11359-22 | 7E-05 cm/cm/°C | ||
Heat distortion temperature | ASTM D648 | 126 °C | |
ISO 75-2/B | 139 °C | ||
ASTM D648 | 142 °C | ||
ISO 75-2/B | 142 °C | ||
ISO 75-22 | 142 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.