PC XANTAR® 24 U

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.20 g/cm³
Melt volume flow rateISO 11337.00 cm³/10min
Shrinkage rateISO 294-40.60 %
Viscosity valueISO 162852.0 ml/g
Water absorption rateISO 620.35 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessM-ScaleISO 2039-270
optical performance Test ConditionTest MethodTest Result
transmissivityASTM D100389.0 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingIEC 60695-11-10,-20V-2
Burning wire flammability indexIEC 60695-2-12800 °C
Burning wire flammability indexIEC 60695-2-12960 °C
Hot filament ignition temperatureIEC 60695-2-13825 °C
Hot filament ignition temperatureIEC 60695-2-13875 °C
Limiting Oxygen IndexISO 4589-226 %
UL flame retardant ratingIEC 60695-11-10,-20V-2
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-22300 MPa
tensile strength YieldISO 527-260.0 MPa
Tensile strainYieldISO 527-26.0 %
Nominal tensile fracture strainISO 527-2>50 %
Flexural modulusISO 1782400 MPa
bending strengthISO 17890.0 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapISO 180/4A80 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC 60093>1.0E+15 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric strengthIEC 60243-129 kV/mm
relative permittivityIEC 602503.00
relative permittivityIEC 602502.90
Dissipation FactorIEC 602506.6E-04
Dissipation FactorIEC 602509.2E-03
Compared to the Leakage Tracking Index (CTI)UL 746PLC 2
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 3
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/A130 °C
vicatISO 306/B50150 °C
ball-indentation hardnessIEC 60695-10-2Pass
Linear coefficient of thermal expansionISO 11359-26.5E-05 cm/cm/°C
thermal conductivity0.24 W/m/K
RTI ElecUL 746130 °C
RTI ElecUL 746130 °C
RTI ImpUL 746125 °C
RTI ImpUL 746130 °C
RTI StrUL 746125 °C
RTI StrUL 746130 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top