PA66 100 W Chem Polymer Company
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 64 J/m |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| FMVSS flammability | FMVSS302 | PASSES | |
| Extreme Oxygen Index | ASTM D2863 | 28 % | |
| UL flame retardant rating | 0.75mm | UL 94 | V-2 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| bending strength | ASTM D790 | 117 MPa | |
| Bending modulus | ASTM D790 | 3100 MPa | |
| elongation | Break | ASTM D638 | 7.0 % |
| Yield | ASTM D638 | 4.5 % | |
| tensile strength | ASTM D638 | 93.1 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Melting temperature | DSC | 257 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 107 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | MD | ASTM D955 | 1.2to1.8 % |
| density | ASTM D792 | 1.16 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 0 |
| Dielectric strength | 3.00mm | ASTM D149 | 17 kV/mm |
| Volume resistivity | ASTM D257 | 1E+18 ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.