Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.10 g/cm3 |
Shrinkage rate | | ASTM D955 | 0.50-0.70 % |
Water absorption rate | | ASTM D570 | 0.20 % |
density | | ASTM D792 | 1.10 g/cm³ |
Shrinkage rate | | ASTM D955 | 0.50to0.70 % |
Water absorption rate | | ASTM D570 | 0.20 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Fracture tensile strength | | ASTM D638 | 52.4 MPa |
elongation at yield | | ASTM D638 | 200 % |
Flexural modulus | | ASTM D790 | 2280 MPa |
bending strength | | ASTM D790 | 82.7 MPa |
Impact strength of cantilever beam gap | | ASTM D256 | 53 J/m |
Suspended wall beam without notch impact strength | | ASTM D256 | 3200 J/m |
tensile strength | Break | ASTM D638 | 52.4 MPa |
elongation | Yield | ASTM D638 | 200 % |
Flexural modulus | | ASTM D790 | 2280 MPa |
bending strength | | ASTM D790 | 82.7 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 53 J/m |
Suspended wall beam without notch impact strength | | ASTM D256 | 3200 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | ASTM D150 | 3.00 |
Dissipation Factor | | ASTM D150 | 0.020 |
Volume resistivity | | ASTM D257 | 3E+16 ohm.cm |
dielectric strength | | ASTM D149 | 23 kV/mm |
Volume resistivity | | ASTM D257 | 3E+16 ohms·cm |
dielectric strength | | ASTM D149 | 23 kV/mm |
dielectric constant | | ASTM D150 | 3.00 |
Dissipation Factor | | ASTM D150 | 0.020 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 160 ℃ |
Heat distortion temperature | | ASTM D648 | 51.7 ℃ |
Heat distortion temperature | | ASTM D648 | 51.7 °C |
Heat distortion temperature | | ASTM D648 | 160 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.