Alkyd BMC 1902

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7922.07 g/cm³
Shrinkage rateASTM D9550.20to0.40 %
Water absorption rateASTM D5700.23 %
hardnessTest ConditionTest MethodTest Result
Barcol HardnessASTM D258370
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
Mechanical propertiesTest ConditionTest MethodTest Result
bending strengthASTM D790162 MPa
compressive strengthASTM D695165 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D256270 J/m
Electrical performanceTest ConditionTest MethodTest Result
dielectric strengthASTM D14912 kV/mm
dielectric constantASTM D1507.10
Dissipation FactorASTM D1500.030
arc resistanceASTM D495180 sec
Compared to the Leakage Tracking Index (CTI)UL 746PLC 1
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648260 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.