Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Alkyd BMC 1902 Glastic Corporation
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Glastic Corporation/BMC 1902 |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256 | 270 J/m |
hardness | Test Condition | Test Method | Glastic Corporation/BMC 1902 |
---|---|---|---|
Barcol Hardness | ASTM D2583 | 70 |
Mechanical properties | Test Condition | Test Method | Glastic Corporation/BMC 1902 |
---|---|---|---|
compressive strength | ASTM D695 | 165 MPa | |
bending strength | ASTM D790 | 162 MPa |
Electrical performance | Test Condition | Test Method | Glastic Corporation/BMC 1902 |
---|---|---|---|
Dissipation Factor | 60Hz | ASTM D150 | 0.030 |
dielectric constant | 60Hz | ASTM D150 | 7.10 |
dielectric strength | ASTM D149 | 12 kV/mm | |
Compared to the Leakage Tracking Index (CTI) | CTI | UL 746 | PLC 1 |
arc resistance | ASTM D495 | 180 sec |
flammability | Test Condition | Test Method | Glastic Corporation/BMC 1902 |
---|---|---|---|
UL flame retardant rating | 6.4mm | UL 94 | HB |
3.2mm | UL 94 | HB | |
1.6mm | UL 94 | HB |
physical property | Test Condition | Test Method | Glastic Corporation/BMC 1902 |
---|---|---|---|
Shrinkage rate | MD | ASTM D955 | 0.20to0.40 % |
Water absorption rate | 23°C,24hr | ASTM D570 | 0.23 % |
density | ASTM D792 | 2.07 g/cm³ |
Thermal performance | Test Condition | Test Method | Glastic Corporation/BMC 1902 |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | ASTM D648 | 260 °C |