Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ISO294-4 | 0.10 % |
Water absorption rate | | ISO62 | 4.0 % |
Shrinkage rate | | ISO294-4 | 0.60 % |
Ejection Temperature | | | 210 °C |
flammability | Test Condition | Test Method | Test Result |
---|
Burning rate 3 | | ISO3795 | <100 mm/min |
UL flame retardant rating | | UL94 | V-0 |
UL flame retardant rating | | UL94 | V-0 |
UL flame retardant rating | | IEC60695-11-10,-20 | V-0 |
UL flame retardant rating | | IEC60695-11-10,-20 | V-0 |
Limiting Oxygen Index | | ISO4589-2 | 32 % |
FMVSS flammability | | FMVSS302 | B |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2 | 8900 Mpa |
Tensile stress | | ISO527-2 | 109 Mpa |
Tensile strain | | ISO527-2 | 2.2 % |
Flexural modulus | | ISO178 | 9000 Mpa |
Bending stress | | ISO178 | 185 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179/1eU | 35 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | -- ohms |
Volume resistivity | | IEC60093 | >1.0E+15 ohms·cm |
dielectric strength | | IEC60243-1 | 37 KV/mm |
CTI | | IEC60112 | 600 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/A | 233 °C |
melting temperature | | ISO11357-3 | 267 °C |
RTI Elec | | UL746 | 160 °C |
RTI Elec | | UL746 | 160 °C |
RTI Elec | | UL746 | 160 °C |
RTI Elec | | UL746 | 160 °C |
TemperatureIndex | | IEC60216 | 160 °C |
TemperatureIndex | | IEC60216 | 190 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.