Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.19 g/cm³ |
Specific volume | | ASTMD792 | 0.830 cm³/g |
density | | ASTMD792 | 1.19 g/cm³ |
melt mass-flow rate | | ASTMD1238 | 2.0 g/10min |
melt mass-flow rate | | ASTMD1238 | 9.0 g/10min |
Shrinkage rate | | 内部方法 | 0.80to1.0 % |
Water absorption rate | | ASTMD570 | 0.19 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTMD785 | 92 |
Rockwell hardness | R-Scale | ASTMD785 | 127 |
optical performance | Test Condition | Test Method | Test Result |
---|
refractive index | | ASTMD542 | 1.600 |
transmissivity | | ASTMD1003 | 85.0 % |
Haze ratio | | ASTMD1003 | 1.0 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
elongation | Break | ASTMD638 | 78 % |
Flexural modulus | | ASTMD790 | 2330 MPa |
tensile strength | Yield | ASTMD638 | 65.5 MPa |
tensile strength | Break | ASTMD638 | 77.9 MPa |
bending strength | | ASTMD790 | 97.2 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 370 J/m |
Impact strength of cantilever beam gap | | ASTMD4812 | 3200 J/m |
Falling hammer impact | | ASTMD3029 | 149 J |
Tensile impact strength | | ASTMD1822 | 578 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dissipation Factor | | ASTMD150 | 1.6E-03 |
Dissipation Factor | | ASTMD150 | 0.026 |
arc resistance | | ASTMD495 | PLC6 |
Compared to the Leakage Tracking Index (CTI) | | UL746 | PLC 3 |
High arc combustion index (HAI) | | UL746 | PLC 3 |
High Voltage Arc Traceability Rate (HVTR) | | UL746 | PLC 3 |
Hot wire ignition (HWI) | | UL746 | PLC 2 |
Volume resistivity | | ASTMD257 | >2.5E+17 ohms·cm |
dielectric strength | | ASTMD149 | 20 kV/mm |
dielectric constant | | ASTMD150 | 3.27 |
dielectric constant | | ASTMD150 | 3.27 |
dielectric constant | | ASTMD150 | 3.10 |
Dissipation Factor | | ASTMD150 | 1.6E-03 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
thermal conductivity | | ASTMC177 | 0.21 W/m/K |
RTI Elec | | UL746 | 130 °C |
RTI Imp | | UL746 | 130 °C |
RTI Str | | UL746 | 130 °C |
| | ASTMD648 | 149 °C |
| | ASTME831 | 8.1E-05 cm/cm/°C |
specific heat | | ASTMC351 | 1260 J/kg/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.