Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO62 | 2.2 % |
viscosity number | | ISO307 | 145 cm³/g |
hardness | Test Condition | Test Method | Test Result |
---|
| | ISO2039-1 | 165 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|
burning rate | | ISO3795 | <100 mm/min |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
Burning wire flammability index | | IEC60695-2-12 | -- °C |
Burning wire flammability index | | IEC60695-2-12 | -- °C |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179/1eU | 28 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 35 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/1A/1 | 4000 Mpa |
Tensile stress | | ISO527-2/1A/5 | 70.0 Mpa |
Tensile strain | | ISO527-2/1A/5 | 10 % |
Flexural modulus | | ISO178 | 3000 Mpa |
Bending stress | | ISO178 | 100 Mpa |
Bending Strain | | ISO178 | 6.5 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | >1.0E+15 ohms |
Volume resistivity | | IEC60093 | >1.0E+13 ohms·cm |
CTI | | IEC60112 | 450 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/Bf | 180 °C |
| | ISO75-2/Af | 68.0 °C |
vicat | | ISO306/A50 | 215 °C |
vicat | | ISO306/B50 | 200 °C |
BallPressure Test | | IEC60695-10-2 | Pass |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.