PBT P7408 TYNE USA
0
- Properties:Glassmineral 40%performance characteristicsimproved impact resistancegood impact resistance
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.10 g/cm3 | |
Shrinkage rate | ASTM D955 | 0.50-0.70 % | |
Water absorption rate | ASTM D570 | 0.20 % | |
density | ASTM D792 | 1.10 g/cm³ | |
Shrinkage rate | ASTM D955 | 0.50to0.70 % | |
Water absorption rate | ASTM D570 | 0.20 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256 | 69 J/m | |
Suspended wall beam without notch impact strength | ASTM D256 | 430 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | Break | ASTM D638 | 75.8 MPa |
elongation | Yield | ASTM D638 | 2.0 % |
Flexural modulus | ASTM D790 | 7580 MPa | |
bending strength | ASTM D790 | 117 MPa | |
Flexural modulus | ASTM D790 | 7580 MPa | |
bending strength | ASTM D790 | 117 MPa | |
Impact strength of cantilever beam gap | ASTM D256 | 69 J/m | |
Suspended wall beam without notch impact strength | ASTM D256 | 430 J/m | |
Fracture tensile strength | ASTM D638 | 75.8 MPa | |
elongation at yield | ASTM D638 | 2.0 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation Factor | ASTM D150 | 0.020 | |
ASTM D150 | 0.020 | ||
Volume resistivity | ASTM D257 | 6E+16 ohms·cm | |
dielectric strength | ASTM D149 | 30 kV/mm | |
dielectric constant | ASTM D150 | 4.00 | |
Volume resistivity | ASTM D257 | 6E+16 ohm.cm | |
dielectric strength | ASTM D149 | 30 kV/mm | |
dielectric constant | ASTM D150 | 4.00 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 210 °C | |
ASTM D648 | 193 ℃ | ||
ASTM D648 | 210 ℃ | ||
ASTM D648 | 193 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.