Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 12086 | 2.14 g/cm³ |
melt mass-flow rate | | ISO 1133 | 3.0 g/10min |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Limiting Oxygen Index | | ASTM D2863 | >95 % |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
MITFoldingEndurance-doublefolds | | ASTM D2176 | 170000 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 650 MPa |
tensile strength | | ISO 527-2 | 30.0 MPa |
Tensile strain | | ISO 527-2 | 350 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | ASTM D150 | 2.06 |
Dissipation Factor | | ASTM D150 | <7.0E-4 |
Dissipation Factor | | ASTM D150 | 4E-04 |
dielectric strength | | ASTM D149 | 64 kV/mm |
dielectric constant | | ASTM D150 | <2.15 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
melting temperature | | ISO 12086 | 258 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.