Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTMD792 | 1.17 g/cm³ | |
melt mass-flow rate | ASTMD1238 | 12 g/10min | |
ASTMD1238 | 16 g/10min | ||
Shrinkage rate | ASTMD955 | 0.40到0.60 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL94 | 5VA | |
UL94 | 5VA | ||
Burning wire flammability index | IEC60695-2-12 | 925 °C | |
IEC60695-2-12 | 925 °C | ||
IEC60695-2-12 | 950 °C | ||
Hot filament ignition temperature | IEC60695-2-13 | 700 °C | |
IEC60695-2-13 | 700 °C | ||
IEC60695-2-13 | 700 °C | ||
UL flame retardant rating | UL94 | V-0 | |
UL94 | 5VB |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTMD256 | 590 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTMD638 | 60.0 MPa | |
elongation | ASTMD638 | 65 % | |
Flexural modulus | ASTMD790 | 2690 MPa | |
bending strength | ASTMD790 | 88.9 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Hot wire ignition (HWI) | UL746 | PLC 2 | |
dielectric strength | ASTMD149 | 18 kV/mm | |
Compared to the Leakage Tracking Index (CTI) | UL746 | >600 V | |
UL746 | PLC 0 | ||
High arc combustion index (HAI) | UL746 | 60.0到120 | |
UL746 | 60.0到120 | ||
UL746 | 60.0到120 | ||
UL746 | PLC 1 | ||
UL746 | PLC 1 | ||
UL746 | PLC 1 | ||
High Voltage Arc Traceability Rate (HVTR) | UL746 | 80.0到150 mm/min | |
UL746 | PLC 3 | ||
Hot wire ignition (HWI) | UL746 | 15到30 sec | |
UL746 | 15到30 sec | ||
UL746 | 30到60 sec | ||
UL746 | PLC 3 | ||
UL746 | PLC 3 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ASTMD648 | 85.0 °C | ||
RTI Elec | UL746 | 60.0 °C | |
RTI Imp | UL746 | 60.0 °C | |
RTI | UL746 | 60.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.