Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D955 | 0.10 % |
Water absorption rate | | ASTM D570 | 0.10 % |
density | | ASTM D792 | 1.89 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 210to320 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTM D638 | 41.4to48.3 MPa |
Flexural modulus | | ASTM D790 | 11700to13100 MPa |
bending strength | | ASTM D790 | 124to152 MPa |
compressive strength | | ASTM D695 | 145to152 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTM D257 | 2E+14 ohms·cm |
dielectric strength | | ASTM D149 | 12 kV/mm |
dielectric constant | | ASTM D150 | 5.15to5.35 |
dielectric constant | | ASTM D150 | 4.80to5.00 |
Dissipation Factor | | ASTM D150 | 0.017to0.019 |
Dissipation Factor | | ASTM D150 | 0.010to0.012 |
arc resistance | | ASTM D495 | 170to180 sec |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 204 °C |
Continuous use temperature | | ASTM D794 | 149 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.