PC/PBT XENOY™ X4830
91
- Properties:High mobilityHigh impact resistanceDimensional stability
- Usages:Automotive Applications
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | ASTM D1238 | 7.0 g/10min | |
Melt volume flow rate | ISO 1133 | 6.00 cm3/10min | |
Shrinkage rate | 内部方法 | 0.70-0.90 % | |
Water absorption rate | ISO 62 | 0.42 % | |
ISO 62 | 0.14 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 105 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | 12 kJ/m² | |
ISO 179/1eA | 40 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak | ||
Impact strength of cantilever beam gap | ISO 180/1A | 9.0 kJ/m² | |
ISO 180/1A | 15 kJ/m² | ||
ISO 180/1A | 45 kJ/m² | ||
Suspended wall beam without notch impact strength | ISO 180/1U | NoBreak | |
ISO 180/1U | NoBreak | ||
Dart impact | ASTM D3763 | 70.0 J | |
ASTM D3763 | 70.0 J | ||
Multi axis Instrumented Impact Energy | ISO 6603-2 | 110 J |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile strain | ISO 527-2/50 | 4.2 % | |
elongation | ASTM D638 | 150 % | |
ASTM D638 | 140 % | ||
Tensile strain | ISO 527-2/5 | 120 % | |
ISO 527-2/50 | 110 % | ||
Flexural modulus | ASTM D790 | 3100 Mpa | |
ISO 178 | 2900 Mpa | ||
bending strength | ISO 178 | 90.0 Mpa | |
ASTM D790 | 96.0 Mpa | ||
Taber abraser | 内部方法 | 30.0 mg | |
tensile strength | ASTM D638 | 60.0 Mpa | |
ISO 527-2/5 | 55.0 Mpa | ||
ISO 527-2/50 | 61.0 Mpa | ||
ASTM D638 | 60.0 Mpa | ||
ASTM D638 | 60.0 Mpa | ||
ISO 527-2/5 | 60.0 Mpa | ||
ISO 527-2/50 | 55.0 Mpa | ||
elongation | ASTM D638 | 4.5 % | |
ASTM D638 | 4.1 % | ||
Tensile strain | ISO 527-2/5 | 4.1 % | |
Tensile modulus | ASTM D638 | 3400 Mpa | |
ISO 527-2/1 | 3200 Mpa | ||
tensile strength | ASTM D638 | 56.0 Mpa |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 125 °C | |
ISO 75-2/Bf | 119 °C | ||
ASTM D648 | 106 °C | ||
ISO 75-2/Af | 97.0 °C | ||
vicat | ASTM D152511 | 133 °C | |
ISO 306/B50 | 133 °C | ||
ISO 306/B120 | 135 °C | ||
Linear coefficient of thermal expansion | ASTME831 | 6E-05 cm/cm/°C | |
ISO 11359-2 | 7.2E-05 cm/cm/°C | ||
ASTME831 | 8.2E-05 cm/cm/°C | ||
ISO 11359-2 | 9E-05 cm/cm/°C | ||
thermal conductivity | ISO 8302 | 0.20 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.