Plastomer, Ethylene-based Premi-Glas® 1200H-15 USA Premix
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Suspended wall beam without notch impact strength | Compression Molded | ASTM D4812 | 590 J/m |
| Impact strength of cantilever beam gap | Compression Molded | ASTM D256 | 430 J/m |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 1.5mm | UL 94 | HB |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | Compression Molded | ASTM D638 | 11700 MPa |
| Poisson's ratio | 0.30 | ||
| compressive strength | ASTM D695 | 145 MPa | |
| bending strength | Compression Molded | ASTM D790 | 96.5 MPa |
| Bending modulus | Compression Molded | ASTM D790 | 9650 MPa |
| tensile strength | Compression Molded | ASTM D638 | 34.5 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| RTI Str | UL 746 | 130 °C | |
| RTI Imp | UL 746 | 130 °C | |
| RTI Elec | UL 746 | 130 °C | |
| thermal conductivity | ASTMC177 | 0.30 W/m/K | |
| Linear coefficient of thermal expansion | TD4 | 3.5E-05 cm/cm/°C | |
| MD3 | 2.5E-05 cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Outdoor applicability | UL 746C | f1 | |
| Shrinkage rate | MD | 0.15to0.25 % | |
| density | 1.70to1.85 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Dielectric strength | ASTM D149 | 15 kV/mm | |
| Arc resistance | ASTM D495 | 180 sec |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.