PC LUVOCOM® 50-0789 LEHVOSS Group
0
- Properties:Fillerscarbon fiber reinforced materials
- Usages:Sports equipmentengineering accessoriesmedical and nursing suppliesbusiness equipment
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Melt volume flow rate | ISO 1133 | 10.0 cm³/10min | |
Shrinkage rate | DIN 16901 | 0.30to0.60 % | |
Water absorption rate | <0.20 % | ||
density | ISO 1183 | 1.24 g/cm³ |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2 | 7000 MPa | |
tensile strength | Break | ISO 527-2 | 110 MPa |
Tensile strain | Yield | ISO 527-2 | 3.0 % |
Flexural modulus | ISO 178 | 5500 MPa | |
bending strength | ISO 178 | 150 MPa | |
Bending Strain | ISO 178 | 4.0 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1fU | 40 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC 60093 | 1E+04 ohms | |
insulation resistance | IEC 60167 | 1E+03 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/A | 147 °C | |
Continuous use temperature | UL 746B | 130 °C | |
maximum service temperature | 150 °C | ||
vicat | ISO 306/A | 160 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.