Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.11 g/cm³ | |
ISO 1183 | 1.11 g/cm³ | ||
melt mass-flow rate | ASTM D1238 | 9.8 g/10min | |
Melt volume flow rate | ISO 1133 | 10.1 cm³/10min | |
Shrinkage rate | 内部方法 | 0.50to0.70 % | |
Water absorption rate | ISO 62 | 0.25 % | |
ISO 62 | 0.050 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-2 | |
UL 94 | V-0 | ||
UL 94 | 5VA |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | Break | ISO 527-2/50 | 77.5 MPa |
elongation | Yield | ASTM D638 | 5.0 % |
Tensile strain | Yield | ISO 527-2/50 | 4.8 % |
elongation | Break | ASTM D638 | 15 % |
Tensile strain | Break | ISO 527-2/50 | 5.7 % |
Flexural modulus | ASTM D790 | 3000 MPa | |
ISO 178 | 2980 MPa | ||
bending strength | ISO 178 | 126 MPa | |
ASTM D790 | 122 MPa | ||
Tensile modulus | ASTM D638 | 2730 MPa | |
ISO 527-2/1 | 3060 MPa | ||
tensile strength | Yield | ASTM D638 | 79.2 MPa |
Yield | ISO 527-2/50 | 80.1 MPa | |
Break | ASTM D638 | 62.2 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256 | 91 J/m | |
ISO 180/1A | 6.1 kJ/m² | ||
ISO 180/1A | 8.1 kJ/m² | ||
Dart impact | ASTM D3763 | 19.3 J | |
Charpy Notched Impact Strength | ISO 179/1eA | 7.9 kJ/m² | |
Impact strength of cantilever beam gap | ASTM D256 | 59 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
arc resistance | ASTM D495 | PLC6 | |
Compared to the Leakage Tracking Index (CTI) | UL 746 | PLC 2 | |
IEC 60112 | PLC 5 | ||
High arc combustion index (HAI) | UL 746 | PLC 0 | |
High Voltage Arc Traceability Rate (HVTR) | UL 746 | PLC 4 | |
Hot wire ignition (HWI) | UL 746 | PLC 0 | |
dielectric strength | IEC 60243-1 | 49 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Imp | UL 746 | 105 °C | |
RTI Str | UL 746 | 110 °C | |
Heat distortion temperature | ASTM D648 | 122 °C | |
ASTM D648 | 134 °C | ||
ASTM D648 | 117 °C | ||
ASTM D648 | 123 °C | ||
ISO 75-2/Af | 119 °C | ||
vicat | ASTM D152510 | 138 °C | |
ISO 306/B50 | 138 °C | ||
ISO 306/B120 | 139 °C | ||
ball-indentation hardness | IEC 60695-10-2 | Pass | |
Linear coefficient of thermal expansion | ASTME831 | 6.1E-05 cm/cm/°C | |
ISO 11359-2 | 6.1E-05 cm/cm/°C | ||
ASTME831 | 6.8E-05 cm/cm/°C | ||
ISO 11359-2 | 6.8E-05 cm/cm/°C | ||
RTI Elec | UL 746 | 110 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.