Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
SpiralFlow2.3 | | 内部方法 | 60.0 CM |
Shrinkage rate | | ISO294-4 | 1.2 % |
Shrinkage rate | | ISO294-4 | 0.30 % |
Water absorption rate | | ISO62 | 3.7to4.3 % |
HumidityAbsorption-62%RH | | ISO1110 | 1.3to1.5 % |
hardness | Test Condition | Test Method | Test Result |
---|
| | ISO2039-1 | 290 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|
Burning rate 6 | | FMVSS302 | <100 mm/min |
FlameRating | | UL94 | HB |
GlowWireFlammability Index | | IEC60695-2-12 | 650 °C |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
ReinforcementContent | | ISO1172 | 50 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179/1eU | 110 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 110 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/1 | 16700 Mpa |
Tensile stress | | ISO527-2/5 | 250 Mpa |
Tensile strain | | ISO527-2/5 | 2.5 % |
Flexural modulus | | ISO178 | 15200 Mpa |
Bending stress | | ISO178 | 380 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | 1E+12 ohms |
Volume resistivity | | IEC60093 | 1E+13 ohms·cm |
CTI | | IEC60112 | 600 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/B | 260 °C |
| | ISO75-2/A | 260 °C |
| | ISO75-2/C | 235 °C |
Melting temperature 5 | | DINEN11357-1 | 262 °C |
| | ISO11359-2 | 1.7E-05 cm/cm/°C |
| | ISO11359-2 | 8.8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.