Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTMD955 | 0.0到0.20 % |
Shrinkage rate | | ASTMD955 | 1.5到1.7 % |
Water absorption rate | | ASTMD570 | 0.10 % |
melt mass-flow rate | | ASTMD1238 | 1.1 g/10min |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTMD785 | 105 |
| | ASTMD2240 | 92 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-0 |
UL flame retardant rating | | UL94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTMD638 | 19700 Mpa |
Tensile modulus | | ISO527-2/1A/1 | 22800 Mpa |
Tensile stress | | ISO527-2/1A/5 | 217 Mpa |
Tensile stress | | ASTMD638 | 201 Mpa |
elongation | | ASTMD638 | 2.0 % |
elongation | | ISO527-2/1A/5 | 2.0 % |
Flexural modulus | | ASTMD790 | 17500 Mpa |
Flexural modulus | | ISO178 | 20500 Mpa |
bending strength | | ASTMD790 | 317 Mpa |
bending strength | | ISO178 | 311 Mpa |
compressive strength | | ASTMD695 | 173 Mpa |
shear strength | | ASTMD732 | 95.1 Mpa |
Poisson's ratio | | 7.58 | 0.42 |
Filling analysis | Test Condition | Test Method | Test Result |
---|
melt viscosity | | ASTMD3835 | 920 Pa·s |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTMD4812 | 750 J/m |
Suspended wall beam without notch impact strength | | ISO180 | 44 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTMD648 | 315 °C |
Glass Transition Temperature | | ASTMD3418 | 150 °C |
| | ASTMD3418 | 340 °C |
| | ASTME831 | 5.2E-06 cm/cm/°C |
specific heat | | DSC | 1130 J/kg/°C |
specific heat | | DSC | 1620 J/kg/°C |
thermal conductivity | | ASTME1530 | 0.37 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.