SPS EA533 DUPONT-DOW US
42
- Properties:Glass fiber reinforcedFiller/fiberglass reinfor30% weight filler
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 0.70-0.90 % | |
ISO 294-4 | 0.15-0.30 % |
Basic performance | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183/B | 1.39 g/cm | |
Water absorption rate | ISO 62 | 0.090 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
bending strength | ISO 178 | 195 Mpa | |
Charpy Notched Impact Strength | ISO 179 | 9.00 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179 | 39.00 KJ/m | |
Impact strength of cantilever beam gap | ISO 180 | 12.0 KJ/m | |
Suspended wall beam without notch impact strength | ISO 180 | 50.0 KJ/m | |
Tensile stress | ISO 527-2 | 125 Mpa | |
fracture strain | ISO 527-2 | 1.9 % | |
Flexural modulus | ISO 178 | 10400 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | IEC 60093 | 1.3E+18 ohm.cm | |
dielectric constant | IEC 60250 | 3.200 | |
Dielectric loss | IEC 60250 | 0.00200 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/B | 245 °C | |
vicat | ISO 306 | 260 °C | |
UL flame retardant rating | UL 94 | V-0 | |
RTI Str | UL 746 | 120 °C | |
RTI Imp | UL 746 | 120 °C | |
RTI Elec | UL 746 | 125 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.