PC T90 XG

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.15 g/cm³
Melt volume flow rateISO 113326.0 cm³/10min
Shrinkage rateISO 294-40.55to0.75 %
Shrinkage rateISO 294-40.55to0.75 %
Water absorption rateISO 620.50 %
Water absorption rateISO 620.20 %
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-2/12400 MPa
tensile strength ISO 527-2/5061.0 MPa
tensile strength ISO 527-2/5056.0 MPa
Tensile strainISO 527-2/505.1 %
Tensile strainISO 527-2/50>50 %
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapISO 180/A18 kJ/m²
Impact strength of cantilever beam gapISO 180/A52 kJ/m²
Suspended wall beam without notch impact strengthISO 180无断裂
Multi axis Instrumented Impact EnergyISO 6603-257.0 J
Multi axis Instrumented Impact EnergyISO 6603-251.0 J
Filling analysisTest ConditionTest MethodTest Result
MeltViscosityISO 11443-A225 Pa·s
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC 600931E+16 ohms
Volume resistivityIEC 600931E+16 ohms·cm
dielectric strengthIEC 60243-135 kV/mm
relative permittivityIEC 602503.10
relative permittivityIEC 602503.00
Dissipation FactorIEC 602502.5E-03
Dissipation FactorIEC 602500.010
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/B130 °C
Heat distortion temperatureISO 75-2/A112 °C
vicatISO 306/B50134 °C
vicatISO 306/B120135 °C
Linear coefficient of thermal expansionISO 11359-27E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-27E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App