Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC T90 XG Covestro - Polycarbonates
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Covestro - Polycarbonates/ T90 XG |
---|---|---|---|
Multi axis Instrumented Impact Energy | -30°C | ISO 6603-2 | 57.0 J |
23°C | ISO 6603-2 | 51.0 J | |
Suspended wall beam without notch impact strength | 23°C | ISO 180 | 无断裂 |
Impact strength of cantilever beam gap | 23°C | ISO 180/A | 52 kJ/m² |
-30°C | ISO 180/A | 18 kJ/m² |
Electrical performance | Test Condition | Test Method | Covestro - Polycarbonates/ T90 XG |
---|---|---|---|
dielectric strength | 23°C,1.00mm | IEC 60243-1 | 35 kV/mm |
relative permittivity | 23°C,1MHz | IEC 60250 | 3.00 |
Volume resistivity | 23°C | IEC 60093 | 1E+16 ohms·cm |
relative permittivity | 23°C,100Hz | IEC 60250 | 3.10 |
Surface Resistivity | IEC 60093 | 1E+16 ohms | |
Dissipation Factor | 23°C,100Hz | IEC 60250 | 2.5E-03 |
23°C,1MHz | IEC 60250 | 0.010 |
Mechanical properties | Test Condition | Test Method | Covestro - Polycarbonates/ T90 XG |
---|---|---|---|
tensile strength | 屈服,23°C | ISO 527-2/50 | 61.0 MPa |
Tensile strain | 屈服,23°C | ISO 527-2/50 | 5.1 % |
tensile strength | 断裂,23°C | ISO 527-2/50 | 56.0 MPa |
Tensile strain | 断裂,23°C | ISO 527-2/50 | >50 % |
Tensile modulus | 23°C | ISO 527-2/1 | 2400 MPa |
Filling analysis | Test Condition | Test Method | Covestro - Polycarbonates/ T90 XG |
---|---|---|---|
MeltViscosity | 260°C | ISO 11443-A | 225 Pa·s |
physical property | Test Condition | Test Method | Covestro - Polycarbonates/ T90 XG |
---|---|---|---|
density | 23°C | ISO 1183 | 1.15 g/cm³ |
Shrinkage rate | TD:260°C,2.00mm | ISO 294-4 | 0.55to0.75 % |
Water absorption rate | 平衡,23°C,50%RH | ISO 62 | 0.20 % |
Shrinkage rate | MD:260°C,2.00mm | ISO 294-4 | 0.55to0.75 % |
Water absorption rate | 饱和,23°C | ISO 62 | 0.50 % |
Melt volume flow rate | 260°C/5.0kg | ISO 1133 | 26.0 cm³/10min |
Thermal performance | Test Condition | Test Method | Covestro - Polycarbonates/ T90 XG |
---|---|---|---|
vicat | -- | ISO 306/B120 | 135 °C |
Linear coefficient of thermal expansion | MD:23到55°C | ISO 11359-2 | 7E-05 cm/cm/°C |
Heat distortion temperature | 0.45MPa,未退火,HDT | ISO 75-2/B | 130 °C |
1.8MPa,未退火,HDT | ISO 75-2/A | 112 °C | |
vicat | -- | ISO 306/B50 | 134 °C |
Linear coefficient of thermal expansion | TD:23到55°C | ISO 11359-2 | 7E-05 cm/cm/°C |
Contact Us
Get App
Top