Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.34to1.87 g/cm³ |
density | | ASTM D1505 | 1.42to1.53 g/cm³ |
Water absorption rate | | ASTM D570 | 0.080to2.9 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
elongation | | ASTM D638 | 4.0to8.0 % |
bending strength | | ASTM D790 | 58.6to254 MPa |
compressive strength | | ASTM D695 | 20.7to237 MPa |
Flexural modulus | | ASTM D790 | 2550to3220 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 18to77 J/m |
film | Test Condition | Test Method | Test Result |
---|
film thickness | | | 24to78 µm |
Secant modulus | | ASTM D882 | 2790to3170 MPa |
tensile strength | Break | ASTM D882 | 192to241 MPa |
elongation | Break | ASTM D882 | 72to95 % |
Elmendorf tear strength | | ASTM D1922 | 6.8to38 g |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTM D257 | 4.0E+12到5.8E+15 ohms·cm |
dielectric strength | | ASTM D149 | 15to310 kV/mm |
dielectric constant | | ASTM D150 | 2.95to3.45 |
Dissipation Factor | | ASTM D150 | 8.0E-4到2.1E-3 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Linear coefficient of thermal expansion | | ASTM D696 | 2.6E-5到4.9E-5 cm/cm/°C |
RTI Elec | | UL 746 | 130to240 °C |
RTI | | UL 746 | 130to210 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.