Material Comparison
Add Comparison Model
Select Products for Comparison (1/4)
Highlight Differences
Hide Same
Product Name / Manufacturer / Model
Grade
Certificates
Reference Price
| impact performance | Test Condition | Test Method | BASF GERMANY/HI-12 |
|---|---|---|---|
| Impact strength of cantilever beam gap | -30°C | ISO 180/A | 11 kJ/m² |
| Impact strength of simply supported beam without notch | -30°C | ISO 179 | 160 kJ/m² |
| Charpy Notched Impact Strength | 23°C | ISO 179 | 30 kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 35.0 kJ/m² |
| 23°C | ISO 180/A | 31 kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | 无断裂 |
| Charpy Notched Impact Strength | -30°C | ISO 179 | 11 kJ/m² |
| mechanical properties | Test Condition | Test Method | BASF GERMANY/HI-12 |
| bending strength | ISO 178 | 58.0 Mpa | |
| tensile strength | Yield,23°C | ISO 527-2 | 40.0 Mpa |
| Tensile strain | Yield,23°C | ISO 527-2 | 2.7 % |
| Tensile modulus | ISO 527-2 | 1900 Mpa | |
| thermal performance | Test Condition | Test Method | BASF GERMANY/HI-12 |
| Vicat softening temperature | -- | ISO 306/B50 | 96.0 °C |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 8.0E-5到1.1E-4 cm/cm/°C |
| Maximum operating temperature | 80 °C | ||
| Vicat softening temperature | -- | ISO 306/A50 | 104 °C |
| thermal conductivity | DIN 52612 | 0.17 W/m/K | |
| Hot deformation temperature | 1.8MPa,Annealed | ISO 75-2/A | 97.0 °C |
| 0.45MPa,Annealed | ISO 75-2/B | 102 °C | |
| Physical properties | Test Condition | Test Method | BASF GERMANY/HI-12 |
| density | ISO 1183 | 1.02 g/cm³ | |
| Shrinkage rate | ISO 294-4 | 0.40-0.70 % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.21 % |
| Melt Volume Flow Rate (MVR) | 220°C/10.0kg | ISO 1133 | 14.0 cm3/10min |
| Water absorption rate | Saturation,23°C | ISO 62 | 1.0 % |
| hardness | Test Condition | Test Method | BASF GERMANY/HI-12 |
| Ball Pressure Test | ISO 2039-1 | 80.0 Mpa | |
| Rockwell hardness | R-Sale | ISO 2039-2 | 101 |
| Electrical performance | Test Condition | Test Method | BASF GERMANY/HI-12 |
| Dielectric constant | 100Hz | IEC 60250 | 2.90 |
| Dissipation factor | 100Hz | IEC 60250 | 5.4E-03 |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | |
| Dielectric constant | 1.00mm,1MHz | 2.80 | |
| Volume resistivity | IEC 60093 | 1E+15 ohms·cm | |
| Dissipation factor | 1MHz | IEC 60250 | 8.2E-03 |
| flammability | Test Condition | Test Method | BASF GERMANY/HI-12 |
| UL flame retardant rating | 3.2mm | UL 94 | HB |
| 1.6mm | UL 94 | HB |