Application Areas:Industrial applications|Automotive sector|Electrical appliances|Lighting applications|Plastic bag
Color:--
Grade:Flame retardant grade
Technical Data Sheet
optical performance
Test Condition
Test Method
Test Result
transmissivity
2540μm
ASTM D1003
88.0 %
turbidity
2540μm
ASTM D1003
1.0 %
Refractive index
ASTM D542
1.586
impact performance
Test Condition
Test Method
Test Result
Impact strength of cantilever beam gap
23°C
ASTM D256
800 J/m
Dart impact
23°C
ASTM D3029
169 J
Impact strength of cantilever beam gap
ASTM D1822
546 kJ/m²
Impact strength of cantilever beam gap
23°C
ASTM D4812
3200 J/m
flammability
Test Condition
Test Method
Test Result
UL flame retardant rating
6.0mm
UL 94
V-0
UL flame retardant rating
0.75mm
UL 94
V-2
Extreme Oxygen Index
ASTM D2863
25 %
mechanical properties
Test Condition
Test Method
Test Result
Taber abraser
1000Cycles,1000g,CS-17Wheel
ASTM D1044
10.0 mg
bending strength
Yield,50.0mmSpan
ASTM D790
93.1 Mpa
Bending modulus
50.0mmSpan
ASTM D790
2340 Mpa
elongation
Break
ASTM D638
110 %
elongation
Yield
ASTM D638
7.0 %
tensile strength
Break
ASTM D638
65.5 Mpa
tensile strength
Yield
ASTM D638
62.1 Mpa
thermal performance
Test Condition
Test Method
Test Result
thermal conductivity
ASTMC177
0.27 W/m/K
RTI Elec
UL 746
130 °C
RTI Str
UL 746
130 °C
RTI Imp
UL 746
130 °C
Hot deformation temperature
0.45MPa,Unannealed,6.40mm
ASTM D648
138 °C
Hot deformation temperature
1.8MPa,Unannealed,6.40mm
ASTM D648
132 °C
Vicat softening temperature
ASTM D15255
154 °C
Linear coefficient of thermal expansion
MD:-40to95°C
ASTME831
6.8E-05 cm/cm/°C
specific heat
ASTMC351
1260 J/kg/°C
Physical properties
Test Condition
Test Method
Test Result
Water absorption rate
Equilibrium,100°C
ASTM D570
0.58 %
Outdoor applicability
UL 746C
f1
Water absorption rate
Equilibrium,23°C
ASTM D570
0.35 %
Water absorption rate
24hr
ASTM D570
0.15 %
Shrinkage rate
MD:3.20mm
Internal Method
0.50-0.70 %
melt mass-flow rate
300°C/1.2kg
ASTM D1238
11 g/10min
density
ASTM D792
1.19 g/cm³
density
ASTM D792
1.20 g/cm³
Specific volume
ASTM D792
0.830 cm³/g
Electrical performance
Test Condition
Test Method
Test Result
Dielectric constant
1MHz
ASTM D150
2.96
Dielectric constant
60Hz
ASTM D150
3.17
Dielectric constant
50Hz
ASTM D150
3.17
Dielectric strength
3.20mm,inAir
ASTM D149
15 KV/mm
Volume resistivity
ASTM D257
>1.0E+17 ohms·cm
Dissipation factor
50Hz
ASTM D150
9E-04
Dissipation factor
1MHz
ASTM D150
0.010
Dissipation factor
60Hz
ASTM D150
9E-04
Hot wire ignition
HWI
UL 746
PLC 4
High voltage arc tracing rate
HVTR
UL 746
PLC 2
Compared to the anti leakage trace index
CTI
UL 746
PLC 2
High arc combustion index
HAI
UL 746
PLC 1
hardness
Test Condition
Test Method
Test Result
Rockwell hardness
M-Sale
ASTM D785
70
Rockwell hardness
R-Sale
ASTM D785
118
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.