- Material Properties:Low temperature resistance|Scratch resistant|Medium viscosity
- Application Areas:Automotive Applications|Industrial accessories
- Color:--
- Grade:Transparent level
Technical Data Sheet
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Shore hardness | ISO 868 | 81 | |
ball-indentation hardness | ISO 2039-1 | 110 Mpa |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat Deflection Temperature | ISO 75-2/B | 122 °C | |
ISO 75-2/A | 108 °C | ||
vicat | ISO 306/A | 135 °C | |
ISO 306/B | 130 °C | ||
Glass Transition Temperature | ISO 11357-2 | 140 °C | |
TemperatureIndex | IEC 216 | 100 °C | |
melting temperature | DSC | 250 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 9E-05 cm/cm/°C | |
ISO 11359-2 | 9E-05 cm/cm/°C |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | HB | |
UL 94 | HB | ||
Burning wire flammability index | IEC 60695-2-12 | 800 °C | |
Hot filament ignition temperature | IEC 60695-2-13 | 775 °C |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak | ||
ISO 179/1eU | NoBreak | ||
Charpy Notched Impact Strength | ISO 179/1eA | 13 kJ/m² | |
ISO 179/1eA | 14 kJ/m² | ||
ISO 179/1eA | 14 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Nominal tensile fracture strain | ISO 527-2/50 | >50 % | |
ISO 527-2/50 | >50 % | ||
Tensile strain | ISO 527-2/50 | 8.0 % | |
ISO 527-2/50 | 5.5 % | ||
OuterFiberStrain Atmospheric Stress | ISO 178 | 9.0 % | |
Tensile modulus | ISO 527-2 | 1400 Mpa | |
ISO 527-2 | 1270 Mpa | ||
flexural modulus | ISO 178 | 1700 Mpa | |
bending strength | ISO 178 | 50.0 Mpa | |
ISO 178 | 90.0 Mpa | ||
tensile strength | ISO 527-2/50 | 60.0 Mpa | |
ISO 527-2/50 | 48.0 Mpa | ||
Tensile creep modulus | ISO 899-1 | 1400 Mpa | |
ISO 899-1 | 700 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation Factor | IEC 60250 | 0.012 | |
IEC 60250 | 0.033 | ||
relative permittivity | IEC 60250 | 3.60 | |
IEC 60250 | 3.20 | ||
Surface Resistivity | IEC 60093 | 1E+13 ohms | |
volume resistivity | IEC 60093 | 1E+16 ohms·cm | |
dielectric strength | IEC 60243-1 | 27 KV/mm | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V | |
IEC 60112 | V |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.02 g/cm³ | |
viscosity number | ISO 307 | >150 cm³/g |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.