HDPE DOW™ KS10100UE DOW USA
267
- Unit Price:US$ 1,582 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:35MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:Injection grade
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Spiral flow length | 2 seconds injection,25℃ | Internal Method | 635 mm |
| Basic Performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| melt mass-flow rate | 190℃/5.0kg | ISO 1133 | 12 g/10min |
| 190℃/2.16kg | ISO 1133 | 4 g/10min | |
| density | ASTM D-792 | 0.953 Mpa |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shore hardness | Shore D,Compression Molded | ISO 868 | 65 |
| Impact strength of cantilever beam gap | Compression Molded | ASTM D-1822 | 85 KJ/m |
| Bending modulus | Compression Molded | ASTM D-790 | 850 Mpa |
| Elongation at Break | Compression Molded | ASTM D-638 | > 1600 % |
| tensile strength | Compression Molded,Break | ASTM D-638 | 27 Mpa |
| Yield,Compression Molded | ASTM D-638 | 25 Mpa | |
| Environmental stress cracking resistance | 50℃,100% Antarox,Compression Molded | ASTM D-1693 | 10 hr |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Vicat softening temperature | ISO 306/A | 128 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | 250℃ | ASTM D-955 | 2.6 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.