PVDF Kynar® 720 ARKEMA CHANGSHU
379
- Unit Price:US$ 12,615 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:52MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
- Material Comparison:PVDF Kynar® 720 ARKEMA FRANCE
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1780 kg/㎥ | |
ASTM D792 | 1.77-1.79 g/㎤ | ||
Shrinkage rate | ISO 294 | 2 % | |
ISO 294 | 2 % | ||
Water absorption rate | ISO 62 | 0.03 % | |
ASTM D570 | 0.01-0.03 % | ||
ISO 62 | 0.015 % | ||
Yirong Index | ISO 1133 | 10 ㎤/10min | |
melt mass-flow rate | ASTM D1238 | 5-26.5 g/10min | |
melt viscosity | ASTM D3835 | 6-12 kPoise |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Shore hardness | ASTM D2240 | 76-80 |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
refractive index | ASTM D542 | 1.42 |
UL | Test Condition | Test Method | Test Result |
---|---|---|---|
Outdoor applicability | UL -746C | f1 | |
UL flame retardant rating | UL 94 | V-0 | |
RTI Elec | UL 746B | 150 °C | |
RTI Imp | UL 746B | 150 °C | |
RTI Str | UL 746B | 150 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527 | 2200 Mpa | |
ASTM D638 | 1380-2310 Mpa | ||
tensile strength | ISO 527 | 54 Mpa | |
ASTM D638 | 44.8-55.2 Mpa | ||
ASTM D638 | 34.5-55.2 Mpa | ||
elongation | ISO 527 | 8 % | |
ASTM D638 | 570 % | ||
ISO 527 | 50 % | ||
ASTM D638 | 20-100 % | ||
bending strength | ASTM D790 | 58.6-75.8 Mpa | |
Flexural modulus | ASTM D790 | 1380-2310 Mpa | |
Impact strength of cantilever beam gap | ASTM D256 | 0.0801-0.214 KJ/m | |
Suspended wall beam without notch impact strength | ASTM D256 | 1.07-4.27 KJ/m | |
Charpy Notched Impact Strength | ISO 179 | 8 kJ/㎡ | |
ISO 179 | 5 kJ/㎡ | ||
ISO 179 | 208 kJ/㎡ | ||
ISO 179 | 189 kJ/㎡ | ||
coefficient of friction | ASTM D1894 | 0.2 | |
ASTM D1894 | 0.14 | ||
Taber wear resistance | ASTM G195 | 5-9 mg/1000cy | |
Compression slip | ASTM D695 | 68.9-103 Mpa |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
Limiting Oxygen Index | ISO 4589 | 43 % | |
ASTM D2863 | 44 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Accumulation resistor | IEC 60093 | 2000000000000 Ω.m | |
Volume resistivity | ASTM D257 | 200000000000000 Ω.cm | |
Surface Resistivity | IEC 60093 | 1000000000000000 Ω | |
dielectric strength | IEC 60243 | 21 KV/mm | |
ASTM D149 | 1.7 KV/mm | ||
dielectric constant | IEC 60250 | 9 | |
IEC 60250 | 7 | ||
ASTM D150 | 4.5-9.5 | ||
Dissipation Factor | IEC 60250 | 0.032 | |
IEC 60250 | 0.214 | ||
ASTM D150 | 0.01-0.21 | ||
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75 | 110 °C | |
ASTM D648 | 105-115 °C | ||
ISO 75 | 132 °C | ||
ASTM D648 | 125-140 °C | ||
vicat | ISO 306 | 139 °C | |
melting temperature | ISO 11357 | 168 °C | |
ASTM D3418 | 165-172 °C | ||
Glass Transition Temperature | ISO 11357 | -40 °C | |
ASTM D7028 | -40.6-38.3 °C | ||
Linear coefficient of thermal expansion | ISO 11359 | 0.00015 m/m/k | |
ASTM D696 | 1.19E-3 cm/cm/℃ | ||
thermal conductivity | ASTM E1461 | 0.17-0.19 W/(m.K) | |
specific heat | 内部测试方法 | 745-958 J/(kg.k) | |
decomposition temperature | 内部测试方法 | 375 °C | |
内部测试方法 | 410 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.