PEI EXTEM™ VH1003-1000 SABIC INNOVATIVE US
250
- Unit Price:US$ 21,366 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:30.1MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Chemical resistance|heat-resisting|Flame retardant|high strength
- Application Areas:Automotive sector|aviation industry
- Color:--
- Grade:--
Technical Data Sheet
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
transmissivity | 2540μm | ASTM D1003 | 58.0 % |
turbidity | 2540μm | ASTM D1003 | 2.0 % |
impact performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dart impact | 23°C,TotalEnergy | ASTM D3763 | 33.9 J |
-30°C | ISO 180/1U | 无断裂 | |
23°C | ASTMD4812 | 无断裂 | |
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 无断裂 |
23°C | ISO 179/1eU | 无断裂 | |
-30°C | ASTM D256 | 74 J/m | |
23°C | ASTM D256 | 69 J/m | |
-30°C | ISO 180/1A | 5.4 kJ/m² | |
23°C | ISO 180/1A | 4.6 kJ/m² |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Burning wire flammability index | 3.20mm | IEC 60695-2-12 | 960 °C |
Hot filament ignition temperature | 3.00mm | IEC 60695-2-13 | 850 °C |
Extreme Oxygen Index | ISO 4589-2 | 45 % |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
crack | ASTM D638 | 50 % | |
ISO 527-2/5 | 17 % | ||
50.0mm span | ASTM D790 | 3170 Mpa | |
yield | ISO 527-2/5 | 8.5 % | |
ASTM D638 | 6.0 % | ||
crack | ISO 527-2/5 | 78.0 Mpa | |
ASTM D638 | 96.5 Mpa | ||
yield | ISO 527-2/5 | 95.0 Mpa | |
ASTM D638 | 96.5 Mpa | ||
--8 | ISO 178 | 3080 Mpa | |
--9 | ISO 178 | 123 Mpa | |
Yield, 100mm span | ASTM D790 | 155 Mpa | |
Fracture, 50.0mm span | ASTM D790 | 159 Mpa | |
--2 | ASTM D638 | 3520 Mpa |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Ball Pressure Test | 125°C | IEC 60695-10-2 | Pass |
1.8MPa, unannealed, 64.0mm span of | ISO 75-2/Af | 228 °C | |
1.8MPa, unannealed, 6.40mm | ASTM D648 | 230 °C | |
1.8MPa, unannealed, 3.20mm | ASTM D648 | 217 °C | |
0.45MPa, unannealed, 6.40mm | ASTM D648 | 237 °C | |
thermal conductivity | ASTME1530 | 0.22 W/m/K | |
Horizontal: 23 to 150 ° C | Across Flow, 23to150℃ | ISO 11359-2 | 5E-05 cm/cm/°C |
Horizontal: -40 to 150 ° C | Across Flow, -40to150°C | ASTME831 | 5E-05 cm/cm/°C |
Flow: 23 to 150 ° C | 23to150℃ | ISO 11359-2 | 5E-05 cm/cm/°C |
Flow: -40 to 150 ° C | -40to150°C | ASTME831 | 5E-05 cm/cm/°C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | 367°C/6.6kg | ASTM D1238 | 16 g/10min |
Melt Volume Flow Rate (MVR) | 360°C/5.0kg | ISO 1133 | 8.50 cm3/10min |
Shrinkage rate | MD1 | Internal Method | 0.50-0.70 % |
MD:3.20mm | Internal Method | 0.50-0.70 % | |
TD:3.20mm | Internal Method | 0.50-0.70 % | |
Water absorption rate | Saturation,23°C | ISO 62 | 1.8 % |
Equilibrium,23°C,50%RH | ISO 62 | 0.60 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation factor | 60Hz | IEC 60250 | 0.025 |
50Hz | IEC 60250 | 0.025 | |
Dielectric constant | 1kHz | ASTM D150 | 3.41 |
100Hz | ASTM D150 | 3.41 | |
Dielectric strength | 3.20mm,inOil | ASTM D149 | 17 KV/mm |
Dissipation factor | 100Hz | IEC 60250 | 8E-03 |
1kHz | IEC 60250 | 1E-03 | |
1MHz | IEC 60250 | 7E-03 | |
Compared to the anti leakage trace index | IEC 60112 | PLC 3 |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Ball Pressure Test | H358/30 | ISO 2039-1 | 141 Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.