PBT VALOX™  420SE0 SABIC INNOVATIVE US

260
  • Unit Price:US$ 4,691 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    30MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details
  • Material Comparison:
    PBT LONGLITE®  4830 TAIWAN CHANGCHUN

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Glass fiber reinforceddimensional stability High rigidityhigh strengthheat-resisting
  • Application Areas:Lawn equipmentGarden equipmentIndustrial applicationsAutomotive External PartsElectrical fieldElectronic fieldArchitectural application fieldOutdoor applicationsElectrical appliancesEngine hood partsMedical suppliesNursing suppliesPlastic bagAutomotive interior partsCastersHousehold goodsPetroleum ApplicationsNatural gas suppliessporting goodsTextile applicationLighting applications
  • Color:--
  • Grade:Injection grade

Material Certification

UL

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest Result
densityASTM D7921.63 g/cm³
Specific volumeASTM D7920.610 cm³/g
densityISO 11831.63 g/cm³
melt mass-flow rateASTM D123842 g/10min
Melt volume flow rateISO 113329.0 cm3/10min
Shrinkage rate内部方法0.10-0.50 %
Shrinkage rate内部方法0.50-0.70 %
Shrinkage rate内部方法0.40-0.80 %
Shrinkage rate内部方法0.50-1.0 %
Water absorption rateISO 620.090 %
Water absorption rateISO 620.070 %
Outdoor applicabilityUL 746Cf2
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessASTM D785119
Rockwell hardnessISO 2039-2119
ball-indentation hardnessISO 2039-1118 Mpa
flammabilityTest ConditionTest MethodTest Result
Limiting Oxygen IndexISO 4589-232 %
UL flame retardant ratingUL 94V-2
UL flame retardant ratingUL 94V-0
UL flame retardant ratingUL 945VA
Burning wire flammability indexIEC 60695-2-12960 °C
Mechanical propertiesTest ConditionTest MethodTest Result
Flexural modulusISO 1789500 Mpa
bending strengthISO 178180 Mpa
bending strengthASTM D790186 Mpa
Taber abraser内部方法22.0 mg
Tensile modulusISO 527-2/110000 Mpa
tensile strength ASTM D638120 Mpa
tensile strength ISO 527-2/5120 Mpa
tensile strength ASTM D638120 Mpa
tensile strength ISO 527-2/5120 Mpa
elongationASTM D6382.0 %
Tensile strainISO 527-2/51.9 %
elongationASTM D6382.0 %
Tensile strainISO 527-2/51.9 %
Flexural modulusASTM D7909800 Mpa
Tensile modulusASTM D63812000 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA6.0 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA7.0 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU50 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU50 kJ/m²
Impact strength of cantilever beam gapASTM D25657 J/m
Impact strength of cantilever beam gapASTM D25660 J/m
Impact strength of cantilever beam gapISO 180/1A6.0 kJ/m²
Impact strength of cantilever beam gapISO 180/1A7.0 kJ/m²
Impact strength of cantilever beam gapASTM D4812620 J/m
Suspended wall beam without notch impact strengthISO 180/1U45 kJ/m²
Suspended wall beam without notch impact strengthISO 180/1U45 kJ/m²
Dart impactASTM D37635.00 J
Electrical performanceTest ConditionTest MethodTest Result
Compared to the Leakage Tracking Index (CTI)UL 746PLC 3
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 3
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 4
High arc combustion index (HAI)UL 746PLC 0
High Voltage Arc Traceability Rate (HVTR)UL 746PLC 4
Hot wire ignition (HWI)UL 746PLC 2
Surface ResistivityIEC 60093>1.0E+15 ohms
Volume resistivityASTM D257>1.0E+15 ohms·cm
Volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric strengthASTM D14924 KV/mm
dielectric strengthASTM D14919 KV/mm
dielectric strengthIEC 60243-123 KV/mm
dielectric strengthIEC 60243-122 KV/mm
dielectric strengthIEC 60243-116 KV/mm
dielectric constantASTM D1503.80
dielectric constantASTM D1503.70
relative permittivityIEC 602503.30
relative permittivityIEC 602503.30
relative permittivityIEC 602503.80
relative permittivityIEC 602503.30
Dissipation FactorASTM D1502E-03
Dissipation FactorASTM D1500.020
Dissipation FactorIEC 602501E-03
Dissipation FactorIEC 602501E-03
Dissipation FactorIEC 602502E-03
Dissipation FactorIEC 602500.010
arc resistanceASTM D495PLC6
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/Be220 °C
Heat distortion temperatureASTM D648200 °C
Heat distortion temperatureISO 75-2/Ae195 °C
Heat distortion temperatureISO 75-2/Af200 °C
vicatASTM D152511200 °C
vicatISO 306/A50220 °C
vicatISO 306/B50200 °C
vicatISO 306/B120200 °C
ball-indentation hardnessIEC 60695-10-2Pass
Linear coefficient of thermal expansionASTME8312.5E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-22.5E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-22.5E-05 cm/cm/°C
Linear coefficient of thermal expansionASTME8318.9E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-28.9E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-21.2E-04 cm/cm/°C
thermal conductivityISO 83020.25 W/m/K
RTI ElecUL 746130 °C
RTI ImpUL 746130 °C
RTI StrUL 746140 °C
Heat distortion temperatureASTM D648212 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.