PA6/66 Ultramid® C3U BK BASF GERMANY
373
- Unit Price:US$ 10,586 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10.5MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:High impact resistance|Flame retardant
- Application Areas:Electronic insulation|Electrical components
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.16 g/cm³ | |
ISO 1183 | 1.16 g/cm³ | ||
Melt volume flow rate | ISO 1133 | 140 cm3/10min | |
Shrinkage rate | 0.80 % | ||
Water absorption rate | ASTM D570 | 8.5 % | |
ISO 62 | 8.5 % | ||
ASTM D570 | 2.9 % | ||
ISO 62 | 2.9 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 100 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | V-0 | ||
UL 94 | V-0 | ||
UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ISO 527-2 | 75.0 Mpa | |
elongation | ASTM D638 | 5.0 % | |
Tensile strain | ISO 527-2 | 4.0 % | |
elongation | ASTM D638 | 50 % | |
Nominal tensile fracture strain | ISO 527-2 | 6.0 % | |
Flexural modulus | ASTM D790 | 3000 Mpa | |
ISO 178 | 3000 Mpa | ||
Tensile modulus | ISO 527-2 | 3500 Mpa | |
tensile strength | ASTM D638 | 83.0 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179 | 4.0 kJ/m² | |
ISO 179 | 9.0 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179 | 80 kJ/m² | |
Impact strength of cantilever beam gap | ASTM D256 | 32 J/m | |
ASTM D256 | 43 J/m | ||
ISO 180 | 4.5 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | ASTM D257 | 1E+13 ohms·cm | |
IEC 60093 | 1E+13 ohms·cm | ||
dielectric strength | IEC 60243-1 | 32 KV/mm | |
dielectric constant | IEC 60250 | 3.60 | |
Dissipation Factor | IEC 60250 | 0.020 | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | 8E-05 cm/cm/°C | ||
9E-05 cm/cm/°C | |||
RTI Elec | UL 746 | 110 °C | |
UL 746 | 120 °C | ||
UL 746 | 120 °C | ||
UL 746 | 120 °C | ||
RTI Imp | UL 746 | 65.0 °C | |
UL 746 | 105 °C | ||
UL 746 | 105 °C | ||
UL 746 | 105 °C | ||
Heat distortion temperature | ASTM D648 | 224 °C | |
ASTM D648 | 91.0 °C | ||
ISO 75-2/A | 70.0 °C | ||
melting temperature | ASTM D3418 | 243 °C | |
ISO 3146 | 243 °C | ||
Linear coefficient of thermal expansion | ASTME831 | 4E-05 cm/cm/°C | |
RTI Str | UL 746 | 65.0 °C | |
UL 746 | 115 °C | ||
UL 746 | 120 °C | ||
UL 746 | 120 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.