
PPA AKROLOY® PA GF 60 NA AKRO-PLASTIC GERMANY
325
- Unit Price:US$ 4,312 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:23MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:Injection grade
Technical Data Sheet
impact performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 90 kJ/m² |
23°C | ISO 179/1eU | 100 kJ/m² |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Burning rate | 1.00 mm | FMVSS 302 | < 100 mm/min |
UL flame retardant rating | 0.8 mm | UL 94 | HB |
Hot filament ignition temperature | 0.8 mm | IEC 60695-2-13 | 650 °C |
filler content | ISO 1172 | 60 % |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2/1 | 21000 Mpa | |
tensile strength | Break | ISO 527-2/5 | 275 Mpa |
Tensile strain | Break | ISO 527-2/5 | 2.5 % |
Bending modulus | ISO 178 | 20000 Mpa | |
bending strength | ISO 178 | 405 Mpa |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 245 °C |
1.8 MPa, Unannealed | ISO 75-2/A | 225 °C | |
Melting temperature | DIN EN 11357-1 | 255 °C | |
Linear coefficient of thermal expansion | Flow : 23 to 80°C | ISO 11359-2 | 1.5E-5 cm/cm/°C |
Across Flow : 23 to 80°C | ISO 11359-2 | 5.5E-5 cm/cm/°C | |
Temperature index - at 50% loss of tensile strength | 110 to 130 °C | ||
140 to 150 °C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Spiral flow length | Internal Method | 47.0 CM | |
Shrinkage rate | 横向Flow | ISO 294-4 | 0.50 % |
Flow | ISO 294-4 | < 0.30 % | |
Water absorption rate | Saturation, 23°C | ISO 62 | 3.0 to 3.5 % |
Humidity Absorption - 62% RH | 70°C | ISO 1110 | 0.80 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Compared to the anti leakage trace index | Solution A | IEC 60112 | PLC 0 |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Ball Pressure Test | H 961/30 | ISO 2039-1 | 330 Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.