PPA Zytel®  HTN51G35HSLBK083 DUPONT BELGIUM

197
  • Unit Price:US$ 4,135 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    30MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Glass fiber reinforcedThermal stabilityFlame retardantHigh temperature resistance
  • Application Areas:Automotive interior partsElectrical appliancesFitness equipment
  • Color:--
  • Grade:Injection grade

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest Result
Water absorption rateISO 624.5 %
Shrinkage rateISO 294-40.60 %
Shrinkage rateISO 294-40.20 %
SpecificHeatCapacity of Melt1860 J/kg/°C
ThermalConductivityofMelt0.25 W/m/K
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessISO 2039-2108
Rockwell hardnessISO 2039-2124
flammabilityTest ConditionTest MethodTest Result
burning rateISO 379523 mm/min
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
UL flame retardant ratingIEC 60695-11-10,-20HB
UL flame retardant ratingIEC 60695-11-10,-20HB
Limiting Oxygen IndexISO 4589-224 %
FMVSS flammabilityFMVSS302B
Supplementary InformationTest ConditionTest MethodTest Result
OdorVDA2704.00
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-212000 Mpa
tensile strength ISO 527-2210 Mpa
Tensile strainISO 527-22.4 %
Tensile creep modulusISO 899-1-- Mpa
Tensile creep modulusISO 899-1-- Mpa
Flexural modulusISO 17810300 Mpa
bending strengthISO 178300 Mpa
Poisson's ratioISO 5270.39
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notchISO 179/1eU60 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU70 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Compared to the Leakage Tracking Index (CTI)IEC 60112 V
Surface ResistivityIEC 60093-- ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric strengthIEC 60243-136 KV/mm
relative permittivityIEC 602504.00
relative permittivityIEC 602504.00
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/B284 °C
Heat distortion temperatureISO 75-2/A260 °C
melting temperatureISO 11357-3300 °C
Linear coefficient of thermal expansionISO 11359-21.8E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-21.8E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-25.5E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-25.5E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top