LCP VECTRA® V140 CELANESE USA
245
- Unit Price:US$ 6,253 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:50MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Glass fiber reinforced|Liquid crystal polymer/polyphenylene sulfide blend|40% glass fiber reinforced
- Application Areas:Automotive Applications|Home appliance components
- Color:--
- Grade:Injection grade
Technical Data Sheet
Basic performance | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1670 kg/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-1 | 16000 Mpa | |
tensile strength | ISO 527-1 | 145 Mpa | |
elongation | ISO 527-1 | 1.0 % | |
Flexural modulus | ISO 178 | 16000 Mpa | |
bending strength | ISO 178 | 230 Mpa | |
Charpy Notched Impact Strength | ISO 179/1eA | 11.0 KJ/m | |
Impact strength of cantilever beam gap | ISO 180/1A | 7.00 KJ/m | |
Rockwell hardness | ISO 2039-2 | 96 M Scale |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
relative permittivity | IEC 60250 | 4.20 | |
IEC 60250 | 3.70 | ||
Dielectric loss | IEC 60250 | 0.020 | |
IEC 60250 | 0.0050 | ||
Compared to the Leakage Traceability Index (CTI) | IEC 60112 | 175 | |
dielectric strength | IEC 60243-1 | 25 KV/mm | |
Surface Resistivity | IEC 60093 | 1E+15 ohms | |
Volume resistivity | IEC 60093 | 1E+12 ohm.m |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-1 | 270 °C | |
Crystallization peak temperature | ISO 11357-1 | 280 °C | |
Linear coefficient of thermal expansion | ISO 11359-1 | 0.000011 cm/cm℃ | |
ISO 11359-1 | 0.000021 cm/cm℃ | ||
combustibility | UL 94 | V-0 | |
UL 94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App