MABS 950-X02 TORAY JAPAN

473
  • Unit Price:US$ 2,826 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    30MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View
+86 ********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Detergent resistantScratch resistant
  • Application Areas:Electrical applicationsOA deviceelectrical equipment
  • Color:--
  • Grade:--

Technical Data Sheet

optical performanceTest ConditionTest MethodTest Result
turbidity3000μmISO 147823.0 %
transmissivityTotal,3000μmISO 1346886.0 %
impact performanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gap23°C,3.20mmASTM D256180 J/m
Charpy Notched Impact Strength23°CISO 17914 kJ/m²
Impact strength of cantilever beam gap23°C,12.7mmASTM D256170 J/m
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
mechanical propertiesTest ConditionTest MethodTest Result
bending strength23°CISO 17871.0 Mpa
bending strengthASTM D79067.0 Mpa
Bending modulus23°CISO 1782180 Mpa
Bending modulusASTM D7902100 Mpa
Tensile strainBreak,23°CISO 527-214 %
elongationBreakASTM D63820 %
tensile strengthYield,23°CISO 527-250.0 Mpa
tensile strengthASTM D63843.0 Mpa
thermal performanceTest ConditionTest MethodTest Result
Vicat softening temperature80.0to85.0 °C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A75.0 °C
Hot deformation temperature1.8MPa,Unannealed,6.40mmASTM D64879.0 °C
Physical propertiesTest ConditionTest MethodTest Result
Shrinkage rateInternal Method0.40-0.60 %
melt mass-flow rate220°C/10.0kgISO 113318 g/10min
density23°CISO 11831.09 g/cm³
densityASTM D7921.09 g/cm³
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-Sale,23°CISO 2039-2110
Rockwell hardnessR-Sale,23°CASTM D785110
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.