PPS Susteel® GS-40 TOSOH JAPAN
346
- Unit Price:US$ 9,739 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:enhance|Glass fiber reinforced
- Application Areas:Fiber grade
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
| other | Test Condition | Test Method | Test Result |
|---|---|---|---|
| characteristic | 韧性良好 | ||
| Color | 黑色 | ||
| purpose | 注射型 |
| machinability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | Across Flow | ASTM D-955 | 0.7 % |
| Flow | ASTM D-955 | 0.3 % | |
| Dry conditions | 120-150度 2.0-5.0hr | ||
| Processing temperature | 270-300 °C | ||
| 290-330 °C | |||
| Screw speed | 100-150 rpm | ||
| Mold temperature | 135-150 °C | ||
| pressure | 1.00-20.0 Mpa |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Elongation at Break | ASTM D-638 | 1.7 % | |
| Tensile Weld Strength | Internal Method | 60.0 Mpa | |
| bending strength | ISO 178 | 275 Mpa | |
| Bending modulus | ISO 178 | 14700 Mpa | |
| Tensile strain | Break | ISO 527-2 | 1.5 % |
| tensile strength | Yield | ISO 527-2 | 176 Mpa |
| Bending modulus | ASTM D-790 | 15 GPa | |
| bending strength | ASTM D-790 | 275 Mpa | |
| Rockwell hardness | ASTM D-785 | 122 | |
| Charpy Notched Impact Strength | Unnotched | ASTM D-256 | 541 J/m |
| 有Notched | ASTM D-256 | 74 J/m | |
| tensile strength | ASTM D-638 | 172 Mpa | |
| Impact strength of cantilever beam gap | ASTM D256/ISO 179 | 82 kg·cm/cm(J/M)ft·lb/in | |
| Elongation at Break | ASTM D638/ISO 527 | 1.5 % | |
| tensile strength | ASTM D638/ISO 527 | 176 kg/cm²(MPa)[Lb/in²] | |
| Bending modulus | ASTM D790/ISO 178 | 14700 kg/cm²(MPa)[Lb/in²] | |
| bending strength | ASTM D790/ISO 178 | 275 kg/cm²(MPa)[Lb/in²] |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | >260 °C |
| Melting temperature | Internal Method | 285 °C | |
| Hot deformation temperature | 1.82MPa | ASTM D-648 | >260 °C |
| UL flame retardant rating | UL 94 | V-0 | |
| Linear coefficient of thermal expansion | 自定标准 | 2.2 | |
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 260 ℃(℉) |
| Melting temperature | 285 ℃(℉) |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | <0.020 % |
| Shrinkage rate | MD | ISO 294-4 | 0.30 % |
| TD | ISO 294-4 | 0.80 % | |
| density | ASTM D792/ISO 1183 | 1.64 | |
| Shrinkage rate | ASTM D955 | 0.3-0.8 % | |
| Water absorption rate | ASTM D570/ISO 62 | 0.02 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | IEC 60093 | 1E+17 ohms·cm | |
| Dielectric strength | IEC 60243-1 | 16 KV/mm | |
| Dielectric constant | 1MHz | IEC 60250 | 3.90 |
| thermal conductivity | 自定标准 | 0.27 W/m.K | |
| Dielectric strength | ASTM D-149 | 16 KV/mm | |
| Dissipation factor | 1MHz | ASTM D-150 | 0.0014 |
| Dielectric constant | 1MHz | ASTM D-150 | 3.9 |
| Volume resistivity | ASTM D-257 | 4×1016 Ω.cm | |
| Dissipation factor | 1MHz | IEC 60250 | 1.4E-03 |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 4 |
| IEC 60112 | PLC 4 | ||
| Dielectric constant | ASTM D150/IEC 60250 | 3.90 |
| Supplementary Information | Test Condition | Test Method | Test Result |
|---|---|---|---|
| BarFlowLength | Internal Method | 175 mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.