PA612 Zytel®  159L DUPONT USA

258
  • Unit Price:US$ 6,244 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    25MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Mineral reinforcementThermal stability
  • Application Areas:Engineering accessoriesAutomotive ApplicationsEngine parts
  • Color:--
  • Grade:Injection grade

Technical Data Sheet Compare

otherTest ConditionTest MethodTest Result
characteristicPA612无筋.润滑。
processabilityTest ConditionTest MethodTest Result
Temperature50-90 °C
Mechanical propertiesTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D256/ISO 1795 kg·cm/cm(J/M)ft·lb/in
tensile strength ASTM D412/ISO 5272400 kg/cm²(MPa)[Lb/in²]
elongationASTM D412/ISO 5274.5 %
Flexural modulusASTM D790/ISO 1782150 kg/cm²(MPa)[Lb/in²]
Tensile modulusISO 527-1/2DAM|2400 Mpa
Tensile modulusISO 527-1/250%RH|1550 Mpa
Charpy Notched Impact StrengthISO 179/1eADAM|4.2 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA50%RH|8 kJ/m²
Impact strength of cantilever beam gapISO 180/1ADAM|4 kJ/m²
Impact strength of cantilever beam gapISO 180/1A50%RH|6 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eUDAM|NB kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU50%RH|NB kJ/m²
Tensile strainISO 527-1/2DAM|4.3 %
Tensile strainISO 527-1/250%RH|19 %
elongation at breakISO 527-1/2DAM|35 %
elongation at breakISO 527-1/250%RH|>50 %
Impact strength of cantilever beam gapISO 180/1ADAM|4.9 kJ/m²
Impact strength of cantilever beam gapISO 180/1A50%RH|4.3 kJ/m²
Charpy Notched Impact StrengthISO 179/1eADAM|4.2 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA50%RH|4 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eUDAM|NB kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU50%RH|NB kJ/m²
Tensile stressISO 527-1/2DAM|62 Mpa
Tensile stressISO 527-1/250%RH|52 Mpa
Physical propertiesTest ConditionTest MethodTest Result
densityASTM D792/ISO 11831060
Electrical performanceTest ConditionTest MethodTest Result
dielectric temperatureISO 75-1/2135 °C
dielectric temperatureISO 75-1/2DAM|62 °C
dielectric temperatureISO 75-1/250%RH|- °C
Linear coefficient of thermal expansionASTM E-831DAM|1.2 10-4/℃
Linear coefficient of thermal expansionASTM E-83150%RH|- 10-4/℃
Linear coefficient of thermal expansionASTM D-831DAM|1.2 10-4/℃
Linear coefficient of thermal expansionASTM D-83150%RH|- 10-4/℃
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648/ISO 7562 ℃(℉)
Melt TemperatureISO 3146CDAM|218 °C
Melt TemperatureISO 3146C50%RH|- °C
vicatISO 306DAM|181 °C
vicatISO 30650%RH|- °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.