PA66 A50H1 BK SOLVAY SHANGHAI
406
- Unit Price:US$ 4,110 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:40.5MT
- Delivery Terms:FOB
- Port of Loading :Shanghai port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:Flame retardant grade
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 90 | kJ/m² |
| 23°C | ISO 179/1eU | 80 kJ/m² | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| European Railways Certifications | R23 | EN 45545-2 | HL3 | |
| R22 | EN 45545-2 | HL3 | ||
| Extreme Oxygen Index | ISO 4589-2 | 33 | % | |
| Hot filament ignition temperature | 1.6 mm | IEC 60695-2-13 | 775 | °C |
| 0.8 mm | IEC 60695-2-13 | 960 | °C | |
| 0.40 mm | IEC 60695-2-13 | 960 | °C | |
| Burning wire flammability index | 3.2 mm | IEC 60695-2-12 | 960 | °C |
| 1.6 mm | IEC 60695-2-12 | 960 | °C | |
| 0.8 mm | IEC 60695-2-12 | 960 | °C | |
| UL flame retardant rating | 3.2 mm | UL 94 | V-0 | |
| 1.6 mm | UL 94 | V-0 | ||
| 0.8 mm | UL 94 | V-0 | ||
| 0.40 mm | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2/1A | 3800 | Mpa |
| tensile strength | Yield, 23°C | ISO 527-2/1A | 85.0 | Mpa |
| Break, 23°C | ISO 527-2/1A | 80.0 | Mpa | |
| Tensile strain | Break, 23°C | ISO 527-2 | 12 | % |
| Bending modulus | 23°C | ASTM D790 | 3800 | Mpa |
| 23°C | ISO 178 | 3700 | Mpa | |
| bending strength | 23°C | ASTM D790 | 125 | Mpa |
| 23°C | ISO 178 | 135 | Mpa | |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| Temperature at the rear of the barrel | 260 to 270 | °C | ||
| Suggested maximum moisture content | 0.20 | % | ||
| drying temperature | 80 | °C | ||
| Mold temperature | 60 to 80 | °C | ||
| Temperature at the front of the material cylinder | 265 to 275 | °C | ||
| Temperature in the middle of the barrel | 265 to 275 | °C | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/Bf | 237 | °C |
| 1.8 MPa, Unannealed | ISO 75-2/Af | 85.0 | °C | |
| Melting temperature | ISO 11357-3 | 263 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 横向Flow | ISO 294-4 | 1.3 | % |
| Flow | ISO 294-4 | 1.5 | % | |
| Water absorption rate | 24 hr, 23°C | ISO 62 | 0.88 | % |
| Equilibrium, 23°C, 50% RH | ISO 62 | 2.7 | % | |
| Outdoor applicability | UL 746C | f1 | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 3.0E+15 | ohms | |
| Volume resistivity | IEC 60093 | 3.0E+15 | ohms·cm | |
| Dielectric strength | 0.800 mm | IEC 60243-1 | 33 | KV/mm |
| Compared to the anti leakage trace index | Solution A | IEC 60112 | PLC 0 | |
| Dissipation factor | IEC 60250 | 0.017 | ||
| Relative permittivity | IEC 60250 | 3.50 | ||
| Dielectric strength | 2.00 mm | IEC 60243-1 | 21 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.