Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA66 A50H1 BK SOLVAY SHANGHAI
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodSOLVAY SHANGHAI/A50H1 BK
Impact strength of simply supported beam without notch23°CISO 179/1eU80 kJ/m²
-30°CISO 179/1eU90 kJ/m²
Mechanical propertiesTest ConditionTest MethodSOLVAY SHANGHAI/A50H1 BK
Tensile modulus23°CISO 527-2/1A3800 Mpa
Tensile strain断裂, 23°CISO 527-212 %
bending strength23°CISO 178135 Mpa
tensile strength 屈服, 23°CISO 527-2/1A85.0 Mpa
Flexural modulus23°CISO 1783700 Mpa
bending strength23°CASTM D790125 Mpa
tensile strength 断裂, 23°CISO 527-2/1A80.0 Mpa
Flexural modulus23°CASTM D7903800 Mpa
Electrical performanceTest ConditionTest MethodSOLVAY SHANGHAI/A50H1 BK
dielectric strength2.00 mmIEC 60243-121 KV/mm
relative permittivityIEC 602503.50
Dissipation FactorIEC 602500.017
Volume resistivityIEC 600933.0E+15 ohms·cm
dielectric strength0.800 mmIEC 60243-133 KV/mm
Compared to the Leakage Tracking Index (CTI)解决方案 AIEC 60112PLC 0
Surface ResistivityIEC 600933.0E+15 ohms
flammabilityTest ConditionTest MethodSOLVAY SHANGHAI/A50H1 BK
European Railways CertificationsR22EN 45545-2HL3
Hot filament ignition temperature0.40 mmIEC 60695-2-13960 °C
UL flame retardant rating0.40 mmUL 94V-0
European Railways CertificationsR23EN 45545-2HL3
UL flame retardant rating1.6 mmUL 94V-0
Burning wire flammability index1.6 mmIEC 60695-2-12960 °C
Hot filament ignition temperature0.8 mmIEC 60695-2-13960 °C
UL flame retardant rating3.2 mmUL 94V-0
Burning wire flammability index0.8 mmIEC 60695-2-12960 °C
3.2 mmIEC 60695-2-12960 °C
UL flame retardant rating0.8 mmUL 94V-0
Limiting Oxygen IndexISO 4589-233 %
Hot filament ignition temperature1.6 mmIEC 60695-2-13775 °C
physical property Test ConditionTest MethodSOLVAY SHANGHAI/A50H1 BK
Water absorption rate平衡, 23°C, 50% RHISO 622.7 %
Outdoor applicabilityUL 746Cf1
Water absorption rate24 hr, 23°CISO 620.88 %
Shrinkage rate流量ISO 294-41.5 %
横向流量ISO 294-41.3 %
Thermal performanceTest ConditionTest MethodSOLVAY SHANGHAI/A50H1 BK
Heat distortion temperature0.45 MPa, 未退火,HDTISO 75-2/Bf237 °C
melting temperatureISO 11357-3263 °C
Heat distortion temperature1.8 MPa, 未退火,HDTISO 75-2/Af85.0 °C
injectionTest ConditionTest MethodSOLVAY SHANGHAI/A50H1 BK
Suggested maximum moisture content0.20 %
Temperature in the middle of the barrel265 to 275 °C
Temperature at the rear of the barrel260 to 270 °C
drying temperature80 °C
Temperature at the front of the material cylinder265 to 275 °C
Temperature60 to 80 °C